ActronControls Leasam BM2-7D-GP 운영 지침
{카테고리_이름} ActronControls Leasam BM2-7D-GP에 대한 운영 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. ActronControls Leasam BM2-7D-GP 2 페이지. Air conditioning control system
BM2 7D 4Z/GP Operating Instructions
AM
23.0
PM
MON
TUE WED THUR FRI
7
CONT
HIGH
MID
LOW
8
FAN
CONTROL
9
TIMECLOCK
PROGRAM
SET
TEMP
10
LIVING
1
OFFICE
3
ON
1
OFF
Press
to START or STOP the Air Conditioner
2
COOL
Press
to select COOLING ONLY operation
3
AUTO
Press
to select AUTO operating mode.
The system automatically selects HEATING or COOLING on demand
HEAT
4
Press
to select HEATING ONLY operation
TIMER
5
Press
to activate the COUNTDOWN TIMER
If the system is ON, it turns OFF after the set period (e.g. sleep timer)
If the system is OFF, it turns ON after the set period (adjust 30 min - 24 Hr)
TIMER
6
After pressing
Press
TIMER
or
7
Mode lights indicate the system operating status
e.g. "RUN" light indicates the compressor is running.
DPO-BM27DOP-1 Subject to change without notice. E&OE. AUG 2008
1
2
ON
SET
EVENT
1
2
3
OFF
TIME CLOCK
1
SAT SUN
ON
OFF ROOM
4
COOL
AUTO
HEAT
RUN TIMER FILTER
5
COOL
AUTO
HEAT
6
TIMER
EXIT
REPEAT
REPEAT
FAMILY
2
BEDROOMS
4
(while the TIMER light is flashing)
to adjust the TIMER duration
Page 2
8
Keep pressing
HIGH, MID, LOW, CONT HIGH, CONT MID, CONT LOW
"CONTINUOUS" air circulation is usually used in COOLING.
SET
Press
9
TEMP
to the room temperature you desire
10
Zone selection (option) allows comfort control of specific areas
The zone lights indicate the active areas in the house, one zone always remains on.
Zone selection increases the efficiency of your Air Conditioner and saves energy
LOCK THE SET POINT RANGE to resist tampering
UPPER LIMIT - Press TIMER
SET
TEMP
Press
LOWER LIMIT - Press TIMER
SET
Press
TEMP
FILTER LIGHT FLASHING
This is a warning after 160 hours of running time, to remind you to check
the RETURN AIR FILTER to see if it needs a clean. To reset : Press
DISPLAY ROOM TEMPERATURE
"Quick Press" TIMER
The room temperature is displayed for 3 seconds, then the display reverts back to set point
VENTILATION MODE
With the system off, Press
DPO-BM27DOP-1 Subject to change without notice. E&OE. AUG 2008
FAN
to cycle through the fan speeds
CONTROL
or
to adjust the SET POINT
usually ~ 22.5
SET
TEMP
then
or
While it is flashing , to set the limits.
SET
TEMP
then
or
While it is flashing , to set the limits.
to check the room temperature (
FAN
CONTROL
to circulate the air.
Page 3
- CONT is Continuous
ON
to turn off
Press
OFF
the system
(default is 28)
(default is 16)
ON
OFF
"ROOM" light flashes )
ON
Press
to stop fan
OFF