Cisco Nexus 9000 Series 매뉴얼 - 페이지 15

{카테고리_이름} Cisco Nexus 9000 Series에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco Nexus 9000 Series 16 페이지. Switch chassis
Cisco Nexus 9000 Series에 대해서도 마찬가지입니다: 빠른 시작 구성 매뉴얼 (6 페이지), 구성 매뉴얼 (32 페이지), 구성 매뉴얼 (32 페이지), 매뉴얼 (30 페이지), 설치 매뉴얼 (12 페이지), 설치 (8 페이지), 빠른 시작 매뉴얼 (14 페이지)

Cisco Nexus 9000 Series 매뉴얼
Installing the Chassis
Before you begin
• Verify that the switch is fully installed and secured to a rack.
• Verify that the switch is adequately grounded to the facility earth ground or to a grounded rack.
• Verify that all of the fan and power supply modules are installed in the chassis. If the chassis has less
Step 1
If the switch has AC power supplies, connect those power supplies to an AC power source as follows:
a) Verify that the AC power source is turned off at the circuit breaker.
b) Plug the power cable into the power receptacle on the power supply.
c) Attach the other end of the power cable to the AC power source.
d) Turn on the power at the circuit breaker.
e) Verify that the power supply is functioning by making sure that the OK LED turns green and the FAULT LED is
off.
Step 2
Listen for the fans; they should begin operating when the power cable is plugged in.
Step 3
After the switch boots, verify that the following LEDs are on:
• Power supply LED—lit and green
If not green, try removing the module part way from its slot and reinstalling it.
• Fan LED—lit and green
If not green, try removing the module part way from its slot and reinstalling it.
• System Status LED—lit and green (if this LED is orange or red, then one or more environmental monitors is reporting
a problem.)
• Link LEDs for the Ethernet connector—Off
than 4 power supplies, there must be a blank module (NXA-PS-BLANK) in the open power supply slot
to maintain the designed airflow.
Starting the Switch
Installing the Chassis
15