Cisco ONS 15600 참조 매뉴얼 - 페이지 9

{카테고리_이름} Cisco ONS 15600에 대한 참조 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco ONS 15600 22 페이지. Install the bay and backplane connections
Cisco ONS 15600에 대해서도 마찬가지입니다: 카드 설정 변경 (14 페이지), 참조 매뉴얼 (29 페이지), 매뉴얼 (10 페이지), 설치 지침 매뉴얼 (14 페이지)

Cisco ONS 15600 참조 매뉴얼
Chapter 1 Shelf and Backplane Hardware
Four visual alarm interfaces via a DB-15 connector that is surge-protected and EMI-filtered. The
visual alarm indication is provided by the TSC card and the signal is connected to the PDU where
LEDs indicate the alarm status and severity.
Environmental (external) alarms and controls (16 inputs and 16 outputs) via wire-wrap pins. The
interface is surge-protected and provides isolation by using an opto-isolator for alarm inputs and
relays for alarm outputs. By connecting to different wire-wrap pins on the CAP/CAP2, the alarm
outputs can be configured for either normally open (NO) or normally closed (NC) operation. Alarms
are initiated by shorting these contacts. The alarm input interface provides a pair of positive and
negative wire-wrap pins.
The isolation and termination meet the intra-building lightning surge specification in Telcordia
GR-1089. The CAP and CAP2 have –48 VDC monitoring with an I
to store the CAP/CAP2 revision information.
Figure 1-8
Figure 1-8
Visual
Alarm
DB-15
If the CAP/CAP2 fails, the node raises an EQPT alarm. You can replace the CAP/CAP2 on an in-service
node without affecting traffic. To replace a CAP, refer to the Cisco ONS 15600 Procedure Guide. Always
replace the CAP during a maintenance window.
shows the CAP faceplate.
CAP Faceplate and Connections
LAN
BITS
RJ-45
IN
BNC
BITS
OUT
Craft
BNC
DB-9
Backplane
connectors
2
Audible
LAN
BITS
RJ-45
OUT
Wire
DB-15
BNC
wrap
pins
BITS
IN
Craft
BNC
DB-9
Cisco ONS 15600 Reference Manual, R8.0
1.6 Customer Access Panel
C interface and nonvolatile memory
Serial Number Label
Part Number Label
Bar Code and
Country of Origin
Labels
Alarm
1-9