DigitaLinx DL-1H1V1U-WP-W 소유자 매뉴얼 - 페이지 15
{카테고리_이름} DigitaLinx DL-1H1V1U-WP-W에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DigitaLinx DL-1H1V1U-WP-W 19 페이지.
RS232 Control and Configuration....continued
Descriptio
Set RS232 Port Baud Rate
Query RS232 Port Baud
Rate
Reset RS232 Port Baud Rate
(Default is 115200)
Set RS232 End Character
Get RS232 End Character
Reset RS232 End Character
to Factory Default
(Default is crlf)
Command
SET UART_B {b}
{b} = [9600]
[19200]
[38400]
[57600]
[115200]
GET UART_B
RESET UART_B
SET UART_E {e}
{e} = [null]
[cr]
[lf]
[crlf]
GET UART_E
RESET UART_E
DL-1H1V1U-WP-W Owners Manual
Example
Command: SET UART_B 9600<CR><LF>
Return: UART_B 9600 <CR><LF>
Command: GET UART_B<CR><LF>
Return: UART_B 9600 <CR><LF>
Command: RESET UART_B<CR><LF>
Return: UART_B 115200 <CR><LF>
Command: SET UART_E cr<CR><LF>
Return: UART_E cr <CR><LF>
Command: GET UART_E<CR><LF>
Return: UART_E cr <CR><LF>
Command: RESET UART_E<CR><LF>
Return: UART_E crlf <CR><LF>
15