Connecting DC Power to IW-6300H-DCW-x-K9
Figure 16: Connecting Internal Ground and AC Power Connection for IW-6300H-AC-X-K9
1
2
Step 4
Use a wire stripper tool to remove the insulation from each wire. Remove only enough wire to provide a solid
connection in the terminal block. The hot wires should have no bare wire exposed after the connection is
made.
Step 5
Insert the ground wire into the internal ground.
Step 6
Insert each hot wire into the AC entry terminal block.
Step 7
Use a Phillips screwdriver to tighten the terminal block set screws to secure the wires in the terminal block.
Step 8
Verify that no bare wire is exposed. If wire is exposed, remove it from the terminal block, adjust the length,
and reinstall.
Step 9
Check your work.
Step 10
Close the access point cover. See
Connecting DC Power to IW-6300H-DCW-x-K9
Warning
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than:10 A. Statement 1005
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022
Installing the Access Point
24
Customer-supplied harness
Customer-supplied cable (ATEX only)
Closing the Access Cover, on page 14
3
Terminal block
for details.
Installing the Access Point