Argo ADIBS13DC 설치 지침 매뉴얼 - 페이지 11
{카테고리_이름} Argo ADIBS13DC에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Argo ADIBS13DC 19 페이지. Split air conditioner system
Argo ADIBS13DC에 대해서도 마찬가지입니다: 사용 설명서 (15 페이지), 사용 설명서 (17 페이지)
End of installation.
D
13 - HOME AUTOMATION WIRING
It is possible to connect the unit to a Home Automation system, according to the following instructions:
14 - DEFAULT SETTING RESET
To operate the unit again with the default setting it is necessary to set the remote control as follows:
Filter: ON
Night Mode / High Power Mode: OFF
Operation mode: AUTO
Flap: AUTO
Set-point: 10°C
At this point, press contemporary the FAN and IFEEL keys of the remote control for more than 5
seconds and release them by pointing the remote control towards the indoor unit.
If the setting is correct you will hear an acoustic signal as confirmation (4 beep).
After the acoustic signal it is necessary to switch OFF and ON the air conditioner to enable the real
reset of the setting. Now the unit starts again operating with the factory setting.
ON/OFF (Terminals O O) - DEFAULT FACTORY STATE: CLOSED
Contact open: the unit does not operate (always OFF) - inputs from
the remote control unit are not processed.
Contact closed: the unit operates in the normal way, according to the
inputs coming from the remote control unit.
ALARM (Terminals L N) :
These terminals are connected to the contact (normally open) of a
power relay (220 VAC, MAX 3A) that is activated every time any alarm
occurs on the unit.
When an alarm occurs, the poles of the terminal block will have a
voltage of 220V - 50Hz Max. electric load: 3A - 240V
11
EN
C
C