End of installation.
D

13 - HOME AUTOMATION WIRING

It is possible to connect the unit to a Home Automation system, according to the following instructions:

14 - DEFAULT SETTING RESET

To operate the unit again with the default setting it is necessary to set the remote control as follows:
Filter: ON
Night Mode / High Power Mode: OFF
Operation mode: AUTO
Flap: AUTO
Set-point: 10°C
At this point, press contemporary the FAN and IFEEL keys of the remote control for more than 5
seconds and release them by pointing the remote control towards the indoor unit.
If the setting is correct you will hear an acoustic signal as confirmation (4 beep).
After the acoustic signal it is necessary to switch OFF and ON the air conditioner to enable the real
reset of the setting. Now the unit starts again operating with the factory setting.
ON/OFF (Terminals O O) - DEFAULT FACTORY STATE: CLOSED
Contact open: the unit does not operate (always OFF) - inputs from
the remote control unit are not processed.
Contact closed: the unit operates in the normal way, according to the
inputs coming from the remote control unit.
ALARM (Terminals L N) :
These terminals are connected to the contact (normally open) of a
power relay (220 VAC, MAX 3A) that is activated every time any alarm
occurs on the unit.
When an alarm occurs, the poles of the terminal block will have a
voltage of 220V - 50Hz Max. electric load: 3A - 240V