digitalview IE-1000 매뉴얼 - 페이지 4
{카테고리_이름} digitalview IE-1000에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. digitalview IE-1000 20 페이지. Image enhancer add-on board
ASSEMBLY NOTES
The IE-1000 is designed for monitor and custom display projects using 1920x1200 or 1920x1080
resolution 10 bit 120Hz TFT panels with connection with compatible Digital View controllers. The
following provides some guidelines for installation and preparation of a finished display solution.
Preparation: Before proceeding it is important to familiarize yourself with the parts making up the
system and the various connectors, mounting holes and general layout of the IE-1000. As much as
possible connectors have been labeled. Guides to connectors and mounting holes are shown in the
following relevant sections.
1. LCD Panel: The IE-1000 is designed for driving 10 bits 120Hz up to 1920x1200 LVDS panels.
Due to the variation between manufacturers of panels signal timing and other panel
characteristics it is important to use the correct Digital View Connection Diagram (which can be
downloaded from the Digital View Controller Solution Generator at
www.digitalview.com/controllers/csg.php) before connecting to a panel.
2. Image Enhancer board, IE-1000 : With reference to the Connection Diagram ensure correct
jumper and dip switches settings to match the target LCD panel. Caution: Handle with care as
static charge may damage electronic components.
3. LCD main controller, eg SVH-1920 : With reference to the Connection Diagram ensure correct
jumper and dip switches settings to match the target LCD panel. Caution: Handle the controller
with care as static charge may damage electronic components.
4. Interconnect LVDS cable : This cable connects between the IE-1000 and DigitalView controllers
for transmittion of LVDS signal and panel power to IE-1000 board. It is recommended to organize
loose wires with cable ties. Care should be taken when placing the cables to avoid signal
interference. Additionally it may be necessary in some systems to add ferrite cores to the cable to
minimize signal noise.
5. Panel power cable : This cable connects between IE-1000 and DigitalView controllers for panel
power.
6. Panel cable for LVDS panel : In order to provide a clean signal it is recommended that LCD
signal cables should not be longer than 61cm (24 inches). It is recommended to organize loose
wires with cable ties. Care should be taken when placing the cables to avoid signal interference.
Additionally it may be necessary in some systems to add ferrite cores to the cable to minimize
signal noise.
7. RS-232 interface : This port is relevant for firmware upgrade only.
8.
Power Input: 12V/24VDC is required, this should be a regulated supply. The power rating
depends on the panel and inverter used. Normally a power supply with at least 15W power
output should adequate. Although the controller provides power regulation for the LCD power
this does not relate to the power supplied to the backlight inverter. If an unregulated power
supply is provided to an inverter any fluctuations in power may affect operation, performance and
lifetime of the inverter and or backlight tubes.
9.
Power and inverter control cable : Different inverter models require different cables and
different pin assignments. Using the wrong cable may damage the inverter.
IMPORTANT NOTES
•
Power Safety: We strongly advise using appropriate insulation for all circuitry.
•
EMI: Shielding will be required for passing certain regulatory emissions tests.
•
Ground: The various PCB mounting holes are connected to the ground plane.