- Hang up the unit at the anchoring brackets by
simultaneously inserting the condensate discharge pipe
into the wall hole.
Lift it by holding it from the sides of the lower base.
To facilitate the operation of fastening it to the bracket,
tilt it slightly towards you.
To make the electrical connection and fasten the
discharge pipe, place a wedge between the air
conditioner and the wall.
When you have finished, inspect carefully to make sure
there are no fissures at the back of the air conditioner
(the insulating gasket must fit firmly against the wall)
particularly in the zone of the grids. (Fig. 12-13)
- If the socket is in proximity to the appliance, simply plug
it in.
3-3 - ELECTRICAL CONNECTION
The air conditioner is equipped with a power cable with
plug (the electrical connection of the unit is Y type with
cable prepared in a special way; any replacement must
only be carried out by the authorized Service Center).
CAUTION
Before connecting the air conditioner, be sure that:
•
The voltage of the main power supply is the same as
the voltage shown on the nameplate.
•
The power supply line has a ground connection and
it is correctly sized for maximum electrical input of
the air conditioner (minimum cable cross-section:
2
1,5mm
).
•
The air conditioner is powered only through a socket
compatible with the plug supplied.
Main switch for disconnection from the supply line must
have a contact separation in all poles that provides
full disconnection under category III overvoltage
conditions.
Fig. 13
10
Fig. 12