External Modules
Step 1
Read the Safety Warnings and disconnect the power supply before you perform any module replacement.
Step 2
Confirm the router is turned off and disconnected from the power supply.
Step 3
Disconnect all port cables connected to the router. Ensure that you do not work on the router with cables still attached to
the router in the event of lightning or surges.
Step 4
Place the chassis on a flat surface.
Step 5
Align hooks on the cover to slots on the chassis base and lower the cover onto chassis base.
Step 6
Slide the cover from the I/O side to the bezel side
Step 7
Install the fourteen screws on both sides of the chassis. Torque to 6-8 in-lbs.
External Modules
This section describes how to install external modules and FRUs in the Cisco 1000 Series Integrated Services
Routers. The information is contained in the following sections:
Warning
Locate External Slots for Modules
This section describes the locations of external modules on the router motherboard.
Install and Upgrade Internal Modules and Field Replaceable Units
4
Only trained and qualified personnel should be allowed to install, replace or service this equipment. Statement
1030.