Predispose the terminals of the wire to connect to
Q
the terminal strip, connect them and secure the
wiring with clamp provided. (See wiring diagrams).
WARNING
Loose wiring may cause the terminal to overheat
or result in unit malfunction. A fire hazard may
also exist. Therefore, be sure all wiring is tightly
connected.
10 - REMOTE CONTROL UNIT INSTALLATION
To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places:
•
In direct sunlight.
•
Behind a curtain or other places where it is covered.
•
More than 8 m. away from the air conditioner.
•
In the path of the air conditioner airstream.
•
Where it may become extremely hot or cold.
•
Where it may be subject to electrical or magnetic noise.
•
Where there is an obstacle between the remote control unit and air conditioner.
WALL-MOUNTED POSITION
•
Momentarily place the remote control unit in the desired mounting position.
•
Verify that the remote control signals are received by the unit from the selected position.
•
Fix the support at the wall with two screws and hang the remote control unit.
TABLE STAND
Place the support on a flat surface making sure that the remote control signals are received by the unit from the selected
position.
Install the condensate drain to the outside with a
G
positive slope, form a trap at the end if necessary.
9
TABLE
WALL
STAND
SUPPORT
EN