Argo AWICS19 설치 지침 매뉴얼 - 페이지 9

{카테고리_이름} Argo AWICS19에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Argo AWICS19 18 페이지. Split air conditioner system

Predispose the terminals of the wire to connect to
Q
the terminal strip, connect them and secure the
wiring with clamp provided. (See wiring diagrams).
WARNING
Loose wiring may cause the terminal to overheat
or result in unit malfunction. A fire hazard may
also exist. Therefore, be sure all wiring is tightly
connected.

10 - REMOTE CONTROL UNIT INSTALLATION

To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places:
In direct sunlight.
Behind a curtain or other places where it is covered.
More than 8 m. away from the air conditioner.
In the path of the air conditioner airstream.
Where it may become extremely hot or cold.
Where it may be subject to electrical or magnetic noise.
Where there is an obstacle between the remote control unit and air conditioner.
WALL-MOUNTED POSITION
Momentarily place the remote control unit in the desired mounting position.
Verify that the remote control signals are received by the unit from the selected position.
Fix the support at the wall with two screws and hang the remote control unit.
TABLE STAND
Place the support on a flat surface making sure that the remote control signals are received by the unit from the selected
position.
Install the condensate drain to the outside with a
G
positive slope, form a trap at the end if necessary.
9
TABLE
WALL
STAND
SUPPORT
EN