Argo LARI-8K 사용 설명서 - 페이지 10

{카테고리_이름} Argo LARI-8K에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Argo LARI-8K 20 페이지.

For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into
the environment.
The dehumidification mode is recommended during autumn and winter.
If used during summer, it is best to leave the flexible pipe attached so that the hot air is discharged towards
the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (see the next chapter, "HOW TO ELIMINATE
CONDENSATE").

3. FAN MODE (FAN)

Press the MODE button to select ventilation until the corresponding icon appears.
In this mode, the fan speed can be adjusted.
The temperature cannot be adjusted.
Manual drainage
Continuous drainage
V 12/21
HOW TO ELIMINATE CONDENSATE
Cooling
This appliance automatically vaporises condensate in the cooling mode.
Ensure that when the unit is operating in cooling mode, the rubber caps
closing the drainage holes on the rear of the appliance are properly
positioned.
When the air conditioner operates in cooling mode, there is no need for
continuous condensate drainage; only in specific weather conditions with very
high air humidity levels may water deposit inside the unit. When the container
is full, on display appears error code "Ft" and block the appliance's operation.
To empty the container, switch the air conditioner off and unplug it. Remove
the cap form the rear drainage hole and direct it over a normal drain.
Ensure that the tube is not twisted or bent. The tube must slope downwards.
Re-close the drainage hole with the cap and resume use of the air conditioner.
Dehumidification
WARNING!
When using the air conditioner in dehumidification mode, it is advisable to
always arrange for continuous drainage, so as to maximise dehumidification
efficiency.
Connect one end of the PVC pipe (not provided) to the upper discharge hole
and place the other end above a drain.
29