Sony XCHR70 기술 매뉴얼 - 페이지 22

{카테고리_이름} Sony XCHR70에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sony XCHR70 32 페이지. Black-and-white video camera module
Sony XCHR70에 대해서도 마찬가지입니다: 브로셔 (4 페이지), 사양 (4 페이지), 치수 (2 페이지), 운영 지침 (2 페이지)

Sony XCHR70 기술 매뉴얼
Setting the shutter speed using trigger pulse width
No HD/VD input (Internal synchronization)
External trigger shutter operation
1
Trigger*
1
Exposure
time (Te)*
Internal VD*
4
Video out*
6
1
WEN
796 H (Binning OFF)
398 H (Binning ON)
*1 This is an external input signal.
*2 Exposure time (Te)
Te = Trigger pulse width + 5 µ s
(The effective trigger pulse width for the external
trigger shutter operation is between 2 µ s and 1/4 s.)
*3 Normal operation is resumed when the trigger
pulse width is 1/3 s or more. The trigger falling
edge restores external trigger shutter operation. At
this time, the 50 ms after the falling edge of the
trigger pulse is an external trigger input inhibition
area. There is no guarantee of operation for any
trigger input in this period.
*4 The internal VD signals are output as long as there is
no external input and the HD/VD signal input/output
switch on the rear panel is set to INT.
2
Exposure
2
time (Te)*
2
T: T=10 µ s or more*
2
Normal operation*
Trigger pulse width
3
*
5
*5 In external trigger operation, the image is output
for the internal VD falling edge after the trigger
falling edge (1 and 2 in the figure). If the period
from the trigger falling edge to the internal VD
falling edge (T in the figure) is under 10 µ s, it is
not defined whether the image is output for the
internal VD falling edge or the image is output for
the next internal VD falling edge. (3 in the figure
shows that the image is output for the next internal
VD). In this case, see WEN since the image and
WEN make up a pair.
*6 With the XC-HR70, a signal synchronized with
VD cycle is not output.
Note
An image is not output correctly when the next trigger
is input before the image for the previous trigger has
been output.
Mode Settings
Mode transition state
External input
inhibition area
External trigger
(50 ms)
3
shutter operation
3
Exposure time
(Te)*
2
T: T=under 10 µ s*
5
3
22