In the new UDP/IP communications, put "52381d" that is UDP port number of controlling VISCA over IP
protocol. Select all the three signals using [Ctrl] + mouse-click and then press [F9] to prompt 'Search and
Replace' dialog box. Put "_2" and "_3" (in case of 3rd camera addition) in the upper 2 edit boxes and then
press [OK] to correct the signal names. Repeat the same operation towards newly created UDP/IP
communication objects.
4. Addition of signals under S-3: CameraSelect Logic
Expand S-3: CameraSelect logic and then display all the objects in Detail View. Add respective signals whose
signal name contain numerical suffix by pressing [Alt] + [+] button.
©2013 Crestron Electronics, Inc.
15 Volvo Drive · Rockleigh, NJ 07647
800.237.2041 / 201.767.3400
Figure 5: Signal name correction using Substring replace