Sony SRG-X400 명령 목록 - 페이지 9

{카테고리_이름} Sony SRG-X400에 대한 명령 목록을 온라인으로 검색하거나 PDF를 다운로드하세요. Sony SRG-X400 41 페이지. Srt introduction
Sony SRG-X400에 대해서도 마찬가지입니다: 매뉴얼 (15 페이지), 기술 매뉴얼 (15 페이지)

Sony SRG-X400 명령 목록

VISCA over IP

Overview of VISCA over IP

With VISCA over IP function, you can control the
camera using VISCA on a controller equipped
with IP communication capabilities via LAN. You
can connect up to 5 controllers simultaneously
on the network.
The communication specifications of VISCA over
IP are as follows:
• Interface
RJ-45 10BASE-T/100BASE-TX/1000BASE-T
(automatically identifying)
• Internet protocol
IPv4
• Transport protocol
UDP
• IP address
Set by the IP setting command (page 41)
• Port address
52381
• Delivery confirmation/Retransmission
control
Depends on the application
In these instructions, the device outputting
commands, such as a computer, is called the
controller, and the device receiving the
command, such as a BRC/SRG series camera, is
called a peripheral device.
The controllers and peripheral devices are
connected to a one-direction ring conforming to
RS-422 standards. On the IP communication
connection, the controllers and peripheral
devices are connected by bus through a LAN.
RS422 connection
IP communication connection
While the IP communication connection, the
address of each device cannot be set in the
VISCA message as it is because the controllers
and peripheral devices that are connected
simultaneously are increased. In this case,
addresses of the controllers and peripheral
devices that are set in the VISCA message are
9
Network