Sony XC-ST30CE 기술 매뉴얼 - 페이지 20
{카테고리_이름} Sony XC-ST30CE에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sony XC-ST30CE 30 페이지. Black-and-white video camera module
Sony XC-ST30CE에 대해서도 마찬가지입니다: 사양 (4 페이지), 사용자 설명서 (31 페이지), 제품 설명서 (2 페이지), 기술 매뉴얼 (31 페이지), 매뉴얼 (4 페이지)
When set to Mode 2 (Reset mode)
Setting the shutter speed using trigger pulse width
External trigger shutter operation
Trigger*
1
Exposure time (Te)*
Video out
1 H to 2 H
4
*
WEN
250 H (EIA)
293 H (CCIR)
*1 This is an external input signal. The trigger
interval should be trigger pulse width + 1 field +
2H period or more. The trigger interval shorter
than described above cannot be ensured. If a
trigger pulse is not input under the prescribed
conditions, the normal operation is ensured several
V after a change in input operation under the
prescribed conditions.
*2 Exposure time (Te)
Te = Trigger pulse width + 97 µ sec (EIA)
Te = Trigger pulse width + 120 µ sec (CCIR)
(The effective trigger pulse width for the external
trigger shutter operation is between 2 µ sec and
1/4 sec.)
*3 Normal operation is resumed when the trigger
pulse width is 1/3 sec or more. The trigger falling
edge restores external trigger shutter operation. At
this time, the 50 msec after the falling edge of the
trigger pulse is an external trigger input inhibition
area. There is no guarantee of operation for any
trigger input in this period.
XC-ST51/ST51CE
XC-ST50/ST50CE
XC-ST30/ST30CE
Trigger pulse width*
2
250 H (EIA)
293 H (CCIR)
Mode transition state
3
Normal operation*
3
5
*
*4 A VD signal is generated 1H to 2H after a trigger
pulse falls, and an image is output in
synchronization with the VD signal.
*5 When the external trigger shutter mode changes
into the normal operation mode, a WEN signal is
output.
Note
An image is not output correctly when the next trigger
is input before the image for the previous trigger has
been output.
Mode Settings
External input
inhibition area
External trigger
(50 msec)
shutter operation
Exposure time
2
(Te)*
1 H to 2 H
4
*
250 H (EIA)
293 H (CCIR)
20