Sony XCD-U100 기술 매뉴얼 - 페이지 14
{카테고리_이름} Sony XCD-U100에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sony XCD-U100 38 페이지. Digital camera module
Sony XCD-U100에 대해서도 마찬가지입니다: 매뉴얼 (4 페이지), 기술 매뉴얼 (39 페이지), 서비스 매뉴얼 (30 페이지), 운영 지침 (2 페이지)
Partial Scan
The partial scan is a function for outputting part of a whole image as a region of interest on the whole image. Based on
the unit cell as the unit, continuous parts can be selected. Only rectangles can be selected. The screen cannot be cut in
convex and L shapes.
Vertical (Vertical Direction)
Cutting by Partial scan mode
Horizontal (Horizontal Direction)
The minimum unit size for partial scan is 32 pixels × 24 lines. The cut-out position can be set in unit of 4 pixels × 4 lines.
For high-speed scanning, set the maximum packet size.
When using multiple cameras at the same time, set a small packet size that falls within the 800 Mbps band.
When using Partial scan mode, set Format7, Mode0.
14