Sony XCD-U100CR 기술 매뉴얼 - 페이지 24

{카테고리_이름} Sony XCD-U100CR에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sony XCD-U100CR 39 페이지. Digital camera module
Sony XCD-U100CR에 대해서도 마찬가지입니다: 매뉴얼 (4 페이지), 기술 매뉴얼 (38 페이지), 서비스 매뉴얼 (30 페이지), 운영 지침 (2 페이지)

Sony XCD-U100CR 기술 매뉴얼
Actual control can be carried out by setting registers
from F0F00800 onward.
ddd indicates the control value expressed as a 12 bit
hexadecimal number.
xxx indicates that any setting made will be ignored.
Brightness control
Address
Data
F0F00800
82000ddd
AE reference control
Address
Data
F0F00804
82000ddd
Sharpness control
Address
Data
F0F00808
82000000
82000007
White balance control
Address
Data
F0F0080C
82BBBRRR
83xxxxxx
86xxxxxx
Hue (G level) control
Address
Data
F0F00810
82000ddd
Saturation control
Address
Data
F0F00814
82000ddd
Gamma control
Address
Data
F0F00818
82000000
82000001
82000002
82000003
24
Adjusts the black level.
Sets the AE reference value.
Sets to the soft image quality.
Sets to the sharp image quality.
Adjusts the white balance
manually.
Adjusts the white balance
automatically.
Perform the one-push auto
white balance function.
Sets the green video level.
Adjusts the color intensity.
Sets Gamma to OFF.
Reverses the black and white.
Sets the gamma curve
equivalent to 0.7.
Sets an optional gamma curve
by a user. (See "LUT.")
Shutter (exposure time) control
Address
Data
F0F0081C
82000ddd
83000xxx
C2000xxx
C3000xxx
F0F00978h
Determines
(To obtain
the optional
this address,
value using
see "The
the 32-bit
formula for
floating-
absolute
point format.
value shutter
control
register
address" on
page 25.)
Gain control
Address
Data
F0F00820
82000ddd
83000xxx
Trigger control
Address
Data
F0F00830
82000000
82010000
820E000d
820F000d
82E00000
82E10000
82EE000d
82EF000d
F0F0062C
80000000
00000000
Trigger Delay control
Address
Data
F0F00834
82000ddd
Controls shutter using the
manually set relative value.
Sets the shutter control to
AUTO (relative value).
Controls shutter using the
manually set absolute value.
Sets the shutter control to
AUTO (absolute value).
After F0F0081C has been set
to the absolute value control,
set the exposure time using
this register.
Set Gain manually.
Set Gain to AUTO.
Sets to Hardware Trigger
Mode0.
Sets to Hardware Trigger
Mode1.
Sets to Hardware Trigger
Mode14.
Sets to Hardware Trigger
Mode15.
Sets to Software Trigger
Mode0.
Sets to Software Trigger
Mode1.
Sets to Software Trigger
Mode14.
Sets to Software Trigger
Mode15.
Outputs a software trigger. In
Trigger Mode0, automatically
resets to 0 when exposure
ends.
In Trigger Mode1, ends
exposure if "0" is set.
Sets Trigger Delay.