CD SECTION
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10 MΩ impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
5. Use the following extension cables and relay connector.
• Extension cable (19P) (Part No. J-2501-011-B)
Relay connector (Part No. J-2501-167-A)
(BD board CN101 to MAIN board CN111)
• Extension cable (17P) (with connector) (Part No. J-2501-167-A)
(CONNECTOR board CN701 to MAIN board CN301)
1. S-CURVE CHECK
BD board
TP (FEO)
TP (VC)
Procedure:
1. Connect oscilloscope to TP (FEO).
2. Connect between TP (FEO) and TP (VC) by lead wire.
3. Connect between TP (AGCCON) and TP (GND) by lead wire.
4. Turn the power ON.
5. Load a disc (YEDS-18) and turn the power ON again and ac-
tuate the focus search. (Actuate the focus search when disc
tray is moving in and out)
6. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within
2.4±0.7 Vp-p.
S-curve waveform
7. After check, remove the lead wire connected in step 2.
Note: • Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
oscilloscope
+
–
symmetry
A
within 2.4 ± 0.7 Vp-p
B
2.
RF LEVEL CHECK
BD board
TP (RF)
TP (VC)
Procedure:
1. Connect oscilloscope to TP (RF).
As TP (RF) and TP (VC) are located at the edge of board, clip
them together with the board using alligator clips.
2. Turn the power ON.
3. Load a disc (YEDS-18) and playback.
4. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
Note: Clear RF signal waveform means that the shape " " can be clearly
distinguished at the center of the waveform.
RF signal waveform
oscilloscope
+
–
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.2 ± 0.2 Vp-p
17