Use the show environment all command to verify that the system is correctly interpreting
Step 6
the information it is receiving from the environmental sensors on the new CI, as follows:
Router# sh env all
Arbiter type 1, backplane type 7505 (id 1)
Power supply #1 is 600W AC (id 1)
Active fault conditions: none
Active trip points: Restart_Inhibit
15 of 15 soft shutdowns remaining before hard shutdown
01234
Dbus slots: XXXXX
card
inlet
RSP(4)
32C/89F
Shutdown temperature source is 'hotpoint' on RSP(4), requested RSP(4)
+12V measured at 12.21
+5V measured at 5.15
-12V measured at -12.03
+24V measured at 23.87
+2.5 reference is 2.49
Router#
Note
The preceding example display is from a Cisco 7505; the displays from the Cisco 7507 and
Cisco 7513 will vary in format, but will display the same essential information. If any other
messages are presented on the console screen (error messages, and so forth), contact a service
representative for assistance; refer to the note following the section "Cisco Connection Online" on
page 39.
This completes the CI installation check for the Cisco 7500 series chassis.
hotpoint
exhaust
46C/114F
48C/118F
Replacing the Chassis Interface (CI) Board in the Cisco 7500 Series Chassis
Checking the CI Installation