Cisco CE 2000 Platform SCE 2000 4xGBE 빠른 시작 매뉴얼 - 페이지 15
{카테고리_이름} Cisco CE 2000 Platform SCE 2000 4xGBE에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco CE 2000 Platform SCE 2000 4xGBE 29 페이지. Service control engine
Table 1
Setup Command Parameters (continued)
Parameter
Access Control List number
list entries (maximum 20 per list)
IP access ACL
telnet ACL
SNMP Configuration
SNMP agent status
GET community names
SET community names
trap managers (maximum 20)
Authentication Failure trap status
enterprise traps status
system administrator
Topology Configuration
connection mode
type of deployment
physically connected link
(cascade topology only)
priority
(cascade topology only)
on-failure behavior
(inline connection mode only)
Admin status of the SCE 2000 after abnormal
boot
Definition
How many ACLs will be necessary? What IP addresses will be
permitted/denied access for each management interface? You may want
ACLs for the following:
Any IP access
Telnet access
SNMP GET access
SNMP SET access
IP address, and whether permitted or denied access.
ID number of the ACL controlling IP access.
ID number of the ACL controlling telnet access.
Enable or disable SNMP management.
Community strings to allow GET access and associated ACLs (maximum
20).
Community strings to allow SET access and associated ACLs (maximum
20).
Trap manager IP address, community string, and SNMP version.
Sets the status of the Authentication Failure traps.
Sets the status of the enterprise traps.
Name of the system administrator.
Is the SCE 2000 installed using inline topology or receive-only topology
using an optical splitter?
Is this a cascade topology, with two SCE 2000 s connected via the cascade
ports? Or is this a single platform topology?
In a cascade deployment this parameter sets the index for the link that this
SCE 2000 is deployed on. The options for SCE 2000 are link-0 or link-1.
In a single- SCE 2000 platform deployment this parameter is not relevant
since one SCE 2000 is deployed on both links. In this case the link
connected to port1-port2 is by default link-0 and the link connected to
port3-port4 is be default link-1.
If this is a cascaded topology, is this SCE 2000 the primary or secondary
SCE 2000?
If this SCE 2000 is deployed inline, should the failure behavior be bypass
or cutoff of the link?
After a reboot due to a failure, should the SCE 2000 remain in a Failure
status or move to operational status provided no other problem was
detected?
15