Cisco Firepower 4100 Series 매뉴얼 - 페이지 3

{카테고리_이름} Cisco Firepower 4100 Series에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco Firepower 4100 Series 8 페이지. Rack-mount and ground the chassis
Cisco Firepower 4100 Series에 대해서도 마찬가지입니다: 제품 설명서 (17 페이지), 매뉴얼 (8 페이지), 유지 관리 및 업그레이드 매뉴얼 (20 페이지), 매뉴얼 (36 페이지), 매뉴얼 (42 페이지), 매뉴얼 (38 페이지)

Cisco Firepower 4100 Series 매뉴얼
Rack-Mount and Ground the Chassis
Warning
Warning
Step 1
Attach a rack mount bracket to each side of the chassis using the six 8-32 x .375-inch Phillips screws provided in the
accessory kit.
Figure 1: Attach the Rack Mount Bracket to the Side of the Chassis
1
Chassis
8-32 x .375-inch Phillips screws (three per side)
3
Step 2
Attach the inner rails to the sides of the chassis:
a) Remove the inner rails from the slide rail assemblies.
b) Align an inner rail with one side of the chassis so that the three keyed slots in the rail align with the three pegs on the
side of the chassis.
Statement 1032 Lifting the Chassis
To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the
handles on modules, such as power supplies, fans, or cards. These types of handles are not designed to
support the weight of the unit.
Statement 1047—Overheating Prevention
To reduce the risk of fire or bodily injury, do not operate the unit in an area that exceeds the maximum
recommended ambient temperature of 104°F (40°C).
2
Rack-mount bracket
Rack-Mount and Ground the Chassis
Rack-Mount the Chassis
3