Cisco GLC-FE-100LX 유지 관리 및 문제 해결 매뉴얼 - 페이지 13
{카테고리_이름} Cisco GLC-FE-100LX에 대한 유지 관리 및 문제 해결 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco GLC-FE-100LX 17 페이지. Small form-factor pluggable (sfp) transceiver modules
Cisco GLC-FE-100LX에 대해서도 마찬가지입니다: 데이터시트 (9 페이지)
1000BASE-
1550
ZX
1000BASE-
1310
BX-D
1000BASE-
1490
BX-U
Configure SFPs
Configure Interface Speed and Duplex Mode
Ethernet interfaces on the switch operate at 10, 100, or 1000 Mbps, or 10,000 Mbps and in either full- or
half-duplex mode. In full-duplex mode, two stations can send and receive traffic at the same time.
Normally, 10-Mbps ports operate in half-duplex mode, which means that stations can either receive or
send traffic.
You cannot configure speed on SFP module ports, but you can configure speed to not negotiate
(nonegotiate) if connected to a device that does not support autonegotiation. However, when a
1000BASE-T SFP module is in the SFP module port, you can configure speed as 10, 100, or 1000 Mbps,
or auto.
You cannot configure duplex mode on SFP module ports unless a 1000BASE-T SFP module or a
100BASE-FX MMF SFP module is in the port. All other SFP modules operate only in full-duplex mode.
When a 1000BASE-T SFP module is in the SFP module port, you can configure duplex mode to
auto or full.
When a 100BASE-FX SFP module is in the SFP module port, you can configure duplex mode to
half or full.
Note: Half-duplex mode is supported on Gigabit Ethernet interfaces. However, you cannot configure these
interfaces to operate in half-duplex mode.
In order to display the information about an optical transceiver installed, use this command: show hw-
module subslot slot/subslot transceiver port idprom.
Use Third Party SFP Modules
The use of third party SFP transceivers with Cisco devices is not supported by Cisco. Cisco-approved SFP
modules have a serial EEPROM that contains the module serial number, the vendor name and ID, a
unique security code, and cyclic redundancy check (CRC). When an SFP module is inserted in the switch,
the switch software reads the EEPROM to verify the serial number, vendor name and vendor ID, and
recomputes the security code and CRC. If the serial number, the vendor name or vendor ID, the security
code, or CRC is invalid, the software generates this security error message and places the interface in an
error-disabled state:
SYS-3-TRANSCEIVER_NOTAPPROVED:Transceiver on port [dec]/[dec] is not supported
Connect a SFP Module to a GBIC Module
The SFP and GBIC is just a connection between the actual laser and the chassis. You need to verify these
in order to connect a SFP module with a GBIC module:
The type of fiber optic cable used: Single Mode or Multi Mode.
The type of physical connection required: SC connector, ST connector, etc.
Troubleshoot SFPs
The Link Does Not Come Up in the Sup720 Module with Line Cards WS-X6724-SFP and WS-
X6748-SFP, Even After a Reboot
This issue is due to an Online Insertion and Removal (OIR) or a reboot that caused the port to move into
the disabled state. This problem most likely occurs in a Supervisor 720 (Sup720) that runs Catalyst OS
(CatOS) versions 8.4(2), 8.4(3) with line cards WS-X6724-SFP and WS-X6748-SFP.
If the port is not in the disabled state before a reboot or OIR, the port remains in operation after the reboot.
However, if the port is in diasbled state before or after a reboot, toggle the negotiation state of the port
before the remote end is connected. Complete these steps in order to toggle the negotiation of the port:
Approximately 70 km,
SMF
which depends on
link loss
SMF
10 km (32,8210 ft)
SMF
10 km (32,8210 ft)