Cisco GS7000 문제 해결

{카테고리_이름} Cisco GS7000에 대한 문제 해결을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco GS7000 4 페이지. Gainmaker node forward local injection module
Cisco GS7000에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (13 페이지), 유지 관리 매뉴얼 (15 페이지), 문제 해결 매뉴얼 (12 페이지)

Cisco GS7000 문제 해결
Troubleshooting
This troubleshooting section lists common problems and their solutions. If a troubleshooting procedure directs
you to replace a module of the node, see
OIB
There are 3 LEDs on the OIB, Heartbeat LED, Communication LED, and Power LED.
Condition
Normal
Power supply
fault
Error #1
Error #2
Error #3
OIB, on page 1
Troubleshooting the node, on page 2
Power
Heartbeat LED
LED
On
Steady blink
Off
Off
On
Not blink
On
Steady blink
On
Not blink
Removing and Replacing
Modules.
Communication
LED
Steady blink
Normal behavior
Off
Check power supply and power supply
voltages. Check cabling and that the
appropriate power shunts are installed in the
launch amplifier.
Not blink
If Heartbeat LED and Communication LED
blink on power up and then stay off, problem
is with boot. Can be a device failure or
software is not loaded. Try cycling power.
Not blink
OS is ok but node control software is not
running or is stuck. If this condition persists
for more than a minute or two after power
up, check all the cables connecting the lid
and launch amplifier. Try cycling power.
Steady blink
This condition should not be possible unless
Heartbeat LED is damaged.
Troubleshooting