Cisco UCS 5108 사양 시트 - 페이지 48

{카테고리_이름} Cisco UCS 5108에 대한 사양 시트을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco UCS 5108 50 페이지. Fnic tunables feature
Cisco UCS 5108에 대해서도 마찬가지입니다: 매뉴얼 (8 페이지)

Cisco UCS 5108 사양 시트
TECHNICAL SPECIFICATIONS

Environmental Specifications

The environmental specifications for the 5108 blade chassis are listed in
Table 27 UCS 5108 Blade Server Environmental Specifications
Parameter
Temperature operating
Temperature nonoperating
Altitude operating
Humidity operating
Humidity nonoperating
Vibration nonoperating
Shock operating
Shock nonoperating
Safety
Emissions
Immunity
Electrostatic discharge
Acoustic
48
Minimum
10°C to 35°C (50°F to 95°F)
-40°C to 65°C (-40°F to 149°F)
0 to 3, 000 m (0 to 10,000 ft.); maximum ambient temperature decreases
by 1° per 300 m
10 to 90%, non-condensing
5 to 93%, non-condensing
2.2 Grms, 10 minutes per axis on each of the three axes
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes
Trapezoidal, 25 G, two drops on each of six faces ΔV: 175 inches per second
each corner on bottom face drop, 90 inches per second each corner on
other five faces
UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1,
CB IEC60950-1, EN
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC*/CB
GB4943-1995, CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR2 2 Class A,
EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3,
KN22 Class A, CNS13438 Class A
Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV
contact discharge without physical damage
Sound power: 68.8 dBA at ambient temperature 23° C measured using
the Dome Method
GOST MsanPiN 001-96
Table
27.
Cisco UCS 5108 Blade Server Chassis