Cisco UCS B250 M2 설치 및 서비스 참고 사항 - 페이지 9
{카테고리_이름} Cisco UCS B250 M2에 대한 설치 및 서비스 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco UCS B250 M2 34 페이지. Extended memory blade server
Installing and Removing a Blade Server Hard Drive
S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
Installing and Removing a Blade Server Hard Drive
There are up to 2 front-accessible, hot-swappable, 2.5-inch drives per blade. An LSI 1064E RAID
controller is embedded in the motherboard (it is not separately replaceable) and it supports RAID 0 and
1. You can remove blade server hard drives without removing the blade server from the chassis. All other
component replacement for a blade server requires removing the blade from the chassis. Unused hard
drive bays should always be covered with cover plates (N20-BBLKD) to assure proper cooling and
ventilation. The chassis is omitted from illustrations here to simplify the drawing.
To prevent ESD damage, wear grounding wrist straps during these procedures and handle modules by
Caution
the carrier edges only.
Seagate SATA disks and Intel or Samsung SATA SSDs are not supported in UCS Manager release 1.2(1)
Note
and cannot be used with servers using UCS Manager release 1.2(1).
Replacing an HDD or SSD with a drive of the same size, model, and manufacturer generally causes few
problems with UCS Manager. If the drive being replaced was part of a RAID array we recommend using
a newly ordered drive of identical size, model, and manufacturer to replace the failed drive. Cisco
recommends following industry standard practice of using drives of the same capacity when creating
RAID volumes. If drives of different capacities are used, the usable portion of the smallest drive will be
used on all drives that make up the RAID volume. Before upgrading or adding an HDD to a running
system, check the service profile in UCS Manager and make sure the new hardware configuration will
be within the parameters allowed by the service profile.
Hard disk and RAID troubleshooting information is in the "Troubleshooting Server Hardware" chapter
of the
Cisco UCS Troubleshooting
Guide.
Cisco UCS B250 Extended Memory Blade Server Installation and Service Note
9
OL-22474-03