Cisco UCS B260 M4 설치 및 서비스 참고 사항 - 페이지 32

{카테고리_이름} Cisco UCS B260 M4에 대한 설치 및 서비스 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco UCS B260 M4 46 페이지. Blade server
Cisco UCS B260 M4에 대해서도 마찬가지입니다: 설치 및 서비스 참고 사항 (50 페이지)

Cisco UCS B260 M4 설치 및 서비스 참고 사항
Installing a New CPU and Heat Sink
Step 2
To ensure proper seating and prevent pin damage, place the CPU alignment tool with the registration marks
aligned, and press the green button on the tool to release the CPU in place.
Step 3
Close the socket latch.
Step 4
Secure the first hook, which has the following icon:
Step 5
Secure the second hook, which has the following icon:
Step 6
If reusing the heat sink, clean off the old thermal compound from the heat sink and CPU.
Step 7
Use the syringe of thermal grease to apply 2 cubic centimeters of the thermal grease (about half of the contents
of the syringe) to the top of the CPU where it will contact the heat sink. Use the pattern shown in the following
figure:
Figure 16: Thermal Grease Application Pattern
Note
Step 8
Replace the heat sinks and tighten the screws in the order shown in the following figure.
Figure 17: Tightening the Heat Sink Screws
Caution
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v4 CPUs
24
CPUs come with two syringes of thermal grease; one with a blue cap and one with a red cap. Use
the syringe with the blue cap. This thermal grease has very specific properties. Thermal grease from
any other sources should not be used because it may lead to damage.
Left and right heat sinks are different and are not interchangeable. They must be installed in the
correct position.
Servicing the Blade Server