Cisco UCS B260 M4 설치 및 서비스 참고 사항 - 페이지 40
{카테고리_이름} Cisco UCS B260 M4에 대한 설치 및 서비스 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco UCS B260 M4 50 페이지. Blade server
Cisco UCS B260 M4에 대해서도 마찬가지입니다: 설치 및 서비스 참고 사항 (46 페이지)
Memory Performance
Figure 18: Logical Representation of Channels
Memory Performance
When configuring your server, consider the following:
• DIMMs within the blade can be of different speeds, but all DIMMs will run at the speed of the DIMM
• No mixing of DIMM type (LRDIMM, RDIMM, TSV-RDIMM) is allowed.
• Your selected CPU(s) can have some affect on performance. CPUs used must be of the same type.
• Mixing DIMM ranks and densities can lower performance.
• Unevenly populating DIMMs between CPUs can lower performance.
Installing a Virtual Interface Card Adapter
Note
You must remove the adapter card to service it.
To install a Cisco VIC 1340 or VIC 1240 in the blade server, follow these steps:
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
32
with the lowest speed.
Servicing the Blade Server