Memory Performance

Figure 18: Logical Representation of Channels
Memory Performance
When configuring your server, consider the following:
• DIMMs within the blade can be of different speeds, but all DIMMs will run at the speed of the DIMM
• No mixing of DIMM type (LRDIMM, RDIMM, TSV-RDIMM) is allowed.
• Your selected CPU(s) can have some affect on performance. CPUs used must be of the same type.
• Mixing DIMM ranks and densities can lower performance.
• Unevenly populating DIMMs between CPUs can lower performance.

Installing a Virtual Interface Card Adapter

Note
You must remove the adapter card to service it.
To install a Cisco VIC 1340 or VIC 1240 in the blade server, follow these steps:
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
32
with the lowest speed.
Servicing the Blade Server