Understanding the E-Series Server LED State
The following table lists the double-wide E-Series Server LEDs and describes the LED colors and state.
Table 9
LED
1
M0
2
M1
3
M2
HOT
D0A
D0F
D1A
D1F
D2A
D2F
ACT
STS
IMC
Hardware Installation Guide for Cisco UCS E-Series Servers
14
Double-Wide E-Series Server LEDs
Color
Off
Green
Amber
Off
Green
Amber
Off
Green
Amber
Green
Amber
Green
Amber
Green
Amber
Green
Amber
Green
Green
Amber
Green
Indicates
No memory is installed in this socket.
Memory M0 is installed.
Memory M0 is installed, but fault is detected.
No memory installed in this socket.
Memory M1 is installed.
Memory M1 is installed, but fault is detected.
No memory is installed in this socket.
Memory M2 is installed.
Memory M2 is installed, but fault is detected.
Temperature is in range.
High temperature is detected on the CPU, power supply,
or other internal sensors.
Status of the hard drive activity. Can be one of the
following:
• Steady—Hard drive is present.
• Blinking—Activity.
• Off—Inactive or there is no power supplied to the CPU.
Fault is detected on the hard drive.
Status of the hard drive activity. Can be one of the
following:
• Steady—Hard drive is present.
• Blinking—Active.
• Off—Inactive or there is no power supplied to the CPU.
Fault is detected on the hard drive.
If an optional hard drive is present, the status of the hard
drive activity can be one of the following:
Steady—Hard drive is present.
•
Blinking—Active.
•
Off—Inactive or there is no power supplied to the
•
CPU.
If there is a PCIe card installed, the LED is steady green.
Fault is detected on the hard drive.
Blinks when the processor is active.
Operation is normal.
Fault is detected on the processor.
Blinks when the CIMC is operating normally.
OL-26447-03