Epson GT-10000 제품 정보 매뉴얼
EPSON GT-10000+
Gamma
correction:
2 types for CRT display
3 types for printer
1 user-defined table
Color
correction:
1 type for CRT display
3 types for printer output (available in
color byte sequence mode and color line
sequence mode)
1 type user-defined
Command level:
ESC/I B7
Interface:
SCSI 2 (two 50-pin half pitch [high
density] connectors)
IEEE 1394 serial bus interface (optional)
Options:
Automatic Document Feeder (ADF)
IEEE 1394 serial bus interface
Supported
documents:
Opaque documents with smooth surfaces
Light source:
Xenon fluorescent lamp
Reliability:
Main unit MCBF: 100,000 cycles of
carriage movements
Dimensions:
Width: 25.8 inches (656 mm)
Depth: 18.0 inches (458 mm)
Height: 6.9 inches (176 mm)
Weight:
Approximately 46.3 lb (21 kg)
Electrical
Input voltage
range:
100 to 120 VAC
220 to 240 VAC; universal auto-switching
Rated frequency:
50 to 60 Hz
Input frequency:
49.5 to 60.5 Hz
Rated current:
100 to 120 VAC: 1.2 A
220 to 240 VAC: 0.7 A
Power
consumption:
Approximately 50 W (without ADF)
Approximately 55 W (with ADF)
Environmental
Temperature:
Operating:
41 to 95 °F (5 to 35 °C);
50 to 89 °F (10 to 32 °C) when using ADF
Storage:
–13 to 140 °F (–25 to 60 °C)
2 - EPSON GT-10000+
Humidity (without
condensation):
Operating
conditions:
Safety Approvals
Safety standards:
EMC:
CE marking
Low Voltage Directive
73/23/EEC:
EMC Directive:
89/336/EEC:
SCSI Interface
Interface type:
Functions:
Logic level:
3/01
Operating: 10 to 80%
Storage: 10 to 85%
Ordinary office or home conditions; avoid
dust, direct sunlight, or strong light
UL 1950 with D3
CSA C22.2 No. 950
EN60950 (VDE)
IEC950 (ROSTEST, PSB)
FCC part 15 subpart B class B
CSA C108.8 class B
AS/NZS3548 class B
CISPR Pub22 class B
CNS13438 class B
EN60950
EN 55022 Class B
EN 61000-3-2
EN 61000-3-3
EN 50082-1
IEC 60801-2
IEC 60801-3
IEC 60801-4
ANSI X3T9.2/375R Revision 10L
(SCSI 2)
BUS FREE phase
ARBITRATION phase
SELECTION/RESELECTION phase
COMMAND phase (the Logical Unit
Number is fixed at 0 and the Command
Link Function is not supported)
DATA phase
DATA IN phase
DATA OUT phase
STATUS phase
MESSAGE phase
MESSAGE IN phase
MESSAGE OUT phase
ATTENTION condition
RESET condition
TTL compatible