Epson Perfection 636 제품 정보
EPSON Perfection 636
Digital halftoning AAS (Auto Area Segmentation, enable/
disable selectable)
3 halftoning modes (A, B, and C) and
4 dither patterns (A, B, C, and D) for
bi-level and quad-level data
Gamma correction 2 types for CRT display
3 types for printer
1 type for user-defined
Color correction
1 type for CRT display
3 types for printer output (available in
color byte sequence mode and color line
sequence mode)
1 type for user-defined
Interfaces
Two SCSI (half pitch 50-pin connectors)
Light source
White cold cathode fluorescent lamp
Reliability
30,000 cycles of carriage movements
(main unit MCBF)
Dimensions
Width: 11.3 inches (287 mm)
Depth: 16.7 inches (425 mm)
Height: 3.4 inches (88 mm)
Weight
Approx. 9.9 lb (4.5 kg)
Electrical
Specification
100 120 V model
Input voltage range
AC 90 to 132 V
Rated frequency
50 to 60 Hz
Input frequency
49.5 to 60.5 Hz
Rated current
0.5 A
Power consumption
Approx. 20 W
Check the label on the back of the scanner for voltage information.
Environmental
Temperature
Operation
41 to 95 °F (5 to 35 °C)
50 to 89 °F (10 to 32 °C) when using the
auto document feeder
Storage
–13 to 140 °F (–25 to 60 °C)
Humidity (without
condensation)
Operation
10% to 80%
20% to 80%, when using the auto
document feeder
Storage
10% to 85%
2 - EPSON Perfection 636
220 240 V model
AC 198 to 264 V ± 10%
0.3 A
10/98
Operating
conditions
Ordinary office or home conditions; avoid
extreme dust, direct sunlight, and strong
light. Make sure the outlet provides
enough power.

Safety Approvals

120 V model
Safety standards
UL 1950 with D3
CSA C22.2 No. 950
EMI
230 V model
Safety standards
EN 60950
EMC EN 55022 (CISPR Pub 22) class B
CE marking
230 V model
Low Voltage Directive 73/23/EECEN
60950
EMC Directive 89/336/EECEN 55022
Class B
EN 61000-3-2
EN 61000-3-3
EN 50082-1

SCSI Interface

Interface type
ANSI X3T9.2/375R Revision 10L
(SCSI-2)
Functions
BUS FREE phase
ARBITRATION phase
SELECTION/RESELECTION phase
COMMAND phase
(the Logical Unit Number is fixed to 0
and the command link function
is not supported)
DATA phase
Data in phase
Data out phase
STATUS phase
MESSAGE phase
MESSAGE IN phase
MESSAGE OUT phase
ATTENTION condition
RESET condition
FCC part 15 subpart B class B
CSA C108.8 class B
AS/NZS 3548 class B
IEC 801-2
IEC 801-3
IEC 801-4