10. Trouble Shooting Guide
10.1 Display information on main control board – see Fig-2
(1) Gate status LED
Gate Status(Position) \ LEDs
Gate in closed position
Gate is opening
Gate in opened position
Gate is closing
Gate stop in the middle
Gate stop in the middle: which means the gate stop by OSC input and at this position the auto close
does not apply. If the gate hit something or mechanical jammed, gate will stop and green and red status
LEDs alternatively flash.
(2) Input LEDs
Inputs LEDs\ Input status
Open input –OPN LED
Pedestrian input – PED LED
Open/Stop/Close – OSC LED
Photo Electric Beam- PEB LED
Encoder input -A
Encoder input -B
(3) Drive Signal LEDs
Drive Signal LEDs\ Output status
Gate opening- Green LED
Gate closing – Red LED
Low speed – Yellow LED
10.2 Trouble Shooting Guide
Malfunction
Possible causes
Gate not open
1) No power
2) Already in opened position
Gate not close
1) Safety input PEB active
2) OPN input active
Gate run little bit
1) No encoder input
then stop and
2) mechanical jammed
DIGIWAY PTY LTD
TROUBLE SHOOTING GUIDE
Status LED-Green (6)
Slow Flash
Fast flash
on
off
Alternatively flash
Input Active
on
on
on
on
On or off
On or off
Input Active
on
on
on
Countermeasure
1) Check the power
2) First time power up, for safety reason, the
controller treated current position as opened
position.
1) Check the safety device, N/O contact
required.
2) Check access control system
1) Aux. power supply fuse
2) power off and disengage the motor and
11
Status LED-Red (7)
on
off
Slow flash
Fast flash
Alternatively flash
Input inactive
off
off
off
off
On or off
On or off
Input inactive
Gate Status
off
Gate opening
off
Gate Closing
off