Installation Instructions
RSX LED
RSX FAO SETTING INSTRUCTIONS
NOTE: If FAO does not need to be adjusted (default setting is maximum output), install luminaire as normal.
1. Loosen six captive screws and remove RSX door to access the luminaire electronics (Fig 23). Set aside for reinstallation.
2. In all RSX family luminaires, the FAO module is in the approximate location shown in figure 24a. Use a flat-head screwdriver
to turn the FAO dial (figure 24b). Note that position 8 is the default setting and the maximum output value (no dimming).
For Contractor Select configurations, refer table 1 on the next sheet for lumen output values.
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
Page #15