2. Installation

2.3 Installation

2.3.1 Gasket

Applicable model: ST400-WP01
Even in environment that do not require drip-proofing, be sure to use the gasket
(accessory provided with OP1). Install the Operator Pendant on a flat, level surface
with the display facing down, and attach the gasket (provided) into the front
bevelled groove from the rear.
Precautions When Handling the Gasket
- Before you install the Operator Panel, make sure that the gasket is attached to the
Operator Panel.
- Gasket that is used for long periods of time or once has been installed on the
panel is scratched or dirty, and may not qualify IP65 dust-proofing and
drop-proofing performance. Replace the gasket periodically or when obvious
scratches or dirt is seen.
- Do not insert the seams of the gasket at the corners of the Operator Panel.
Inserting the seams of the gasket at the corners of the Operator Panel may cause a
tensile force to the seams and the gasket may be torn.
- To ensure stable dust-proof and drip-proof, attach the gasket so that its seams
come approximately 50 mm right or left to the middle of product bottom side.