13
LED ENABLE/DISABLE SETTING -
JUMPER "JP3" (FIG.4)
Position On (right) - LED ENABLE
The RED LED will activate when the SRDT-15
Is in alarm condition.
Position Off (left) - LED DISABLE
The LEDS are disabled.
Note: the state of the Jumper "JP3" does not
affect the operation of the relay.
When an intrusion is detected, the LED will
activate and the alarm relay will switch into alarm
condition for 1.6 sec.
LED INDICATORS (Fig.4)
YELLOW LED - MW detection's
GREEN
LED - PIR detection's
RED
LED - Alarm
16
FIG. 6 - LONG RANGE CURTAIN LENS
5m
TOP VIEW
(16.4ft)
0
5m
(16.4ft)
20m
5m
10m
15m
0
(16.4ft)
(32.8ft)
(49.2ft)
(65.6ft)
SIDE VIEW
2.1m
(6.9ft)
20m
5m
10m
15m
0
(16.4ft)
(32.8ft)
(49.2ft)
(65.6ft)
19
LENSES-INTERCHANGEABLE HARD
TYPE SPHERICAL LENSES PATTERNS
COVERAGE
WIDE
LONG RANGE ANIMAL
ANGLE
CURTAIN
ALLEY,
18m x 18m
30m x 2m
18m x 18m
(60ft x 60ft) (100ft x 6.3ft) (60ft x 60ft) (50ft x .3ft)
+10%
+10%
TOTAL
ZONES
52*
12
*
18 long range, 16 intermediate, 10 short range,
6 nearest range, 2 creep zones.
REPLACING THE LENS
1. Remove the front cover by inserting a flat
screwdriver in the appropriate slot.
2. Using a small flat screwdriver, press on left or
right side of the installed lens, which will then pop
out, from its side right and left holding pins.
3. Select the desired lens and hold it while making
sure its upper holding pin is pointed upwards.
4. Snap the lens to its place by pressing again
from outside of the front cover until a click is
heard, confirming the new lens is tightly inserted.
5. Replace front cover.
22
TECHNICAL SPECIFICATIONS (CONT.)
Operating Temperature
-20°C to +50°C(-4°F to +122°F)
RFI Protection
30V/m 10 - 1000MHz
EMI Protection
50,000V of electrical interference
from lightning or power through
Visible Light Protection
stable against halogen light 2.4 m
(8ft )or reflected light
MW center frequency
2.45 GHz
MW output power
min + 5 dBm IERP
MW harmonic emission
-20 dBm
Dimensions
137mm x 70mm x 53mm
(5.3" x 2.8" x 2.1")
Weight
130 gr. (4.,6 oz)
CROW reserves the rights to change
specifications without prior notice
7121287_D
TEST PROCEDURES.
Wait one-minute warm-up time after applying
12 Vdc power. Conduct testing with the protected
area cleared of all people.
Walk test
1. Remove front cover.
Set LED to ON position.
2. Reassemble the front cover.
3. Start walking slowly across the detection zone.
4. Observe that the red LED lights whenever
motion is detected.
5. Allow 5 sec. between each test for the detector
to stabilize.
6. After the walk test is completed, you can set the
LED to OFF position.
NOTE:
Walk tests should be conducted, at least once a
year, to confirm proper operation and coverage of
the detector.
PATTERN SCALE CALIBRATION
To calibrate the MW pattern scale, You need the
size of the room (length and detection angle).
For Doppler pattern see fig.7 and table1 on
Page 18, where H – Doppler pattern max;
## - zone number;
a – angle;
3m
(9.9ft)
X,Y – appropriate coordinates of
Doppler pattern.
The potentiometer RV1(Fig. 4) adjusts the
25m
30m
(82ft)
(98.4ft)
detection pattern scale between 30% and 100%
(factory set to 70%). Rotate the potentiometer
clockwise to increase pattern scale.
Rotate the potentiometer counter-clockwise to
25m
30m
decrease pattern scale.
(82ft)
(98.4ft)
The potentiometer at min. " – " is equivalent to a
distance of 6m - 8m.
FIG. 8 - REPLACING THE LENS
CURTAIN
15m x 1m
18
22
CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the
products directly from Crow or from its authorized distributor.
Crow warrants these products to be free from defects in materials and workmanship under normal use and
service for a period of 24 months from the last day of the week and year whose numbers are printed on the
printed circuit board inside these products (hereunder the "Warranty Period").
Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole
discretion and subject to Crow's procedures, as such procedures are form time to time, to repair or replace, free
of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal
use and service. Repaired products shall be warranted for the remainder of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to
Crow for repair or replacement shall be borne solely by the Purchaser.
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become
defective) due to: (a) alteration of the products (or any part thereof) by anyone other than Crow; (b) accident,
abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d)
failure caused by software or hardware which Crow did not provide; (e) use or storage other than in accordance
with Crow's specified operating and storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular
purpose or otherwise, which extend beyond the description on the face hereof.
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole
and exclusive liability toward the Purchaser in connection with the products, including without limitation - for
defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities,
whether oral, written, (non-mandatory) statutory, contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of
profit, and whether occasioned by negligence of the Crow or any third party on its behalf) for breach of this or
any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not
represent that these products can not be compromised or circumvented; that these products will prevent any
person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these products will in all
cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of
burglary, fire, robbery or other events occurring without providing an alarm, but it is not insurance or a
guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on
claim that these products failed to give any warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products,
regardless of cause or origin, Crow's maximum liability shall not in any case exceed the purchase price of these
products, which shall be the complete and exclusive remedy against Crow.
14
FIG. 5 - WA PIR + MW DETECTION
PATTERN
2.1m
17
FIG. 7 - MW PATTERN
Y
Table 1:
##
0
a
180 °
X
0
Y
10 ,5
X,Y are corresponds (m) of pattern points
when H=30m
20
TECHNICAL SPECIFICATIONS
Detection Method
Power Input
Current Draw
Temperature
Compensation
Alarm Period
Alarm Output
Tamper Switch
Warm Up Period
LED Indicator
23
ISRAEL:
USA:
AUSTRALIA:
POLAND:
LATIN AMERICA:
ITALY:
These instructions supersede all previous issues in circulation prior to June 2005.
15
TOP VIEW
WA lens pattern 105 ° (PIR)
15m
MW pattern
10m
5m
0m
18m
30m
5m
10m
15m
SIDE VIEW
5m
10m
18m
30m
18
X
10
2
9
3
1
8
4
5
7
6
1
2
3
4
5
6
7
8
9
130 °
100 °
84 °
75 °
70 °
60 °
52 °
40 °
30 °
3
6
9
12
15
18
21
24
27
6,09
7,15
6,98
8,01
10 ,5
10 ,39 10 ,24
8,73
7,23
21
Dual element PIR & microwave pulse
Doppler
8.2 to 16 Vdc
Active :
25.5 mA
Standby: 16.5 mA
YES
2 +/- 1 sec
N.C 28Vdc 0.1 A with 10 Ohm series
protection resistors
N.C 28Vdc 0.1A with 10 Ohm series
protection resistor - open when cover
is removed
1 min
Yellow LED is blinking during warm up
period and self testing,
Red LED is ON during alarm
Red LED: UNIT ALARM
Green LED: PIR CHANNEL
Yellow LED: MW CHANNEL
24
CROW ELECTRONIC ENGINEERING LTD.
Crow Electronic Engineering Ltd.
12 Kineret St. Airport City, 70100
PO. Box 293 Ben Gurion Airport
Tel: 972-3-9726000
Fax: 972-3-9726001
E-mail:
2160 North Central Road,
Fort Lee, N.J. 07024
Tel: 1-800-GET CROW
or
(201) 944 0005
Fax: (201) 944 1199
E-mail:
429 Nepean HWY Brighton East Vic 3187
Tel: 61-3-9596 7222
Fax: 61-3-9596 0888
E-mail:
VIDICON SP. ZO. O.
15 Povazkowska St.
01 – 797 Warsaw Poland
Tel: 48 22 562 3000
Fax: 48 22 562 3030
E-mail:
CROW LATIN AMERICA
ST
5753 NW 151
.Street
MIAMI LAKES,
FL 33014 – USA
Tel: +1-305-823-8700
Fax: +1-305-823-8711
E-mail:
DEATRONIC
VIA Giulianello 4/14
00178 ROMA, ITALY
Tel: +39-0676-12912
Fax: +39-0676-12601
E-mail:
10
20 °
28 ,5
5,03