The program light will come on steady, indicating readiness to accept new
programming.
To load, for example, user code 3 with a code 43210, key in the following
sequence:
[PROGRAM] 3 [ENTER] 43210 [ENTER]
(If there is an existing code already in that address it will be flashed back on
the key pad display. Entering the new code will delete the old and the new
code will be flashed back to you).
The panel will give 3 short beeps to indicate correct entry or 1 long tone if not
accepted.
To remove or clear a user code number 1234 from user 3, key in the following
sequence
[PROGRAM] 3 [ENTER] [BYPASS] [ENTER]
To exit out of program mode key [PROGRAM] [ENTER]
To change dialler phone numbers:
Your panel will accept up to 6 phone numbers. Your panel can be can be
programmed to dial all or any of these depending on the event which has
occurred.
(The six phone numbers are at program address 221 through to 226)
Making sure the panel is not armed, key in the following sequence:
[PROGRAM] MASTERCODE [ENTER] followed by
[PROGRAM]221 [ENTER]
The current phone number at this address will be flashed back to you on the
keypad LEDs. If this is not the number you wish to change try the next
address, 222 and so on till you locate the number you wish to change.
Simply key in the new numbers then press [ENTER]
The new numbers will be flashed back to confirm acceptance.
To exit out of program mode key [PROGRAM] [ENTER]
(Note: on the key pad 0 is indicated by LED 'A' and 9 by LED 'B')
The MEMORY Key
Your PW-16 alarm panel has an event memory which stores, the 225 most
recent events including all alarm events, all system events such as mains
failure etc as well as settings and un-settings. This event memory is displayed
via the keypad with the most recent event shown first and subsequent events
following in descending order from newest to oldest. Each event is separated
by a beep tone.
There are a number of events which are stored in memory which do not have a
specific indicator associated with them such as Panic and Duress.
events such as tampers and low battery are shared across many devices. For
this reason the following table has been created.
indicator lights correspond to which events in memory.
To view the event memory, press the [MEMORY] button. To clear flashing
memory LED press the [MEMORY] then [ENTER] keys.
EVENT
DEVICE
ACTIVATION
Zones 1-8
ACTIVATION
Zones 9-16
BYPASS
Zones 1-8
BYPASS
Zones 9-16
DETECTOR TAMPER
Zones 1-8
DETECTOR TAMPER
Zones 9-16
CABINET TAMPER
Cabinet or Satellite Siren
WRONG CODE ALARM
Keypad Tamper
LOW BATTERY
Controller Battery
MAINS FAILURE
Controller Mains Supply
LOW BATTERY
Wireless PIR
Zone 1-8
LOW BATTERY
Wireless PIR
Zone 19-16
Other
This table details which
INDICATOR
STATUS
LED's 1-8
On Steady
LED's 1-8
On Steady
AUX.
On Steady
BYPASS
On Steady
LED's 1-8
On Steady
BYPASS
On Steady
LED's 1-8
On Steady
AUX.
On Steady
TAMPER
Flashing
LED's 1-8
On Steady
TAMPER
Flashing
LED's 1-8
On Steady
AUX.
On Steady
TAMPER
Flashing
TAMPER
On Steady
BATTERY
Flashing
MAINS
Flashing
BATTERY
Flashing
LED's 1-8
On Steady
BATTERY
Flashing
LED's 1-8
On Steady
AUX.
On Steady