CROW ELECTRONIC ENGINEERING LTD. MRX-220N 매뉴얼
{카테고리_이름} CROW ELECTRONIC ENGINEERING LTD. MRX-220N에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CROW ELECTRONIC ENGINEERING LTD. MRX-220N 2 페이지. Outdoor double dual mirror optics passive infrared & microwave detector
1
MRX-220N
OUTDOOR DOUBLE DUAL
MIRROR OPTICS
PASSIVE INFRARED &
MICROWAVE DETECTOR
ELECTRONIC ENGINEERING LTD.
INSTALLATION INSTRUCTIONS
P/N: 7101296 REV.A A.Y.
4
MOUNTING THE DETECTOR
Choose a location most likely to intercept an
intruder. See detection pattern in FIG.: 7. The
DOUBLE DUAL high quality sensor detects
motion crossing the beam; it is less sensitive
detecting motion towards the detector.
The MRX-220N performs best when provided with
a constant and stable environment.
The bracket provides MRX-220N installation on
the wall and on the pole, allows changing the
installation angle (vertically and horizontally) in
wide range (FIG.2).
AVOID THE FOLLOWING LOCATIONS
∗ Facing direct sunlight.
∗ Facing areas subject to rapid temperature
changes.
∗ Areas with air ducts or substantial air flows.
∗ Facing metal doors.
NOTE
:
Recommended installation height is 2.4m.
7
FIG. 3 -
TERMINAL BLOCK CONNECTIONS
1
2
3
4
5
6
RELAY
12V
NC
C
NO EOL TAMPER EOL
Terminal 1 - Marked " - " (GND)
Connect to the ground of the control panel.
Terminal 2 - Marked " + " (+12V)
Connect to a positive Voltage of 8.2 -16Vdc
source (usually from the alarm control unit)
Terminals 3,4 & 5 - Marked " NC C NO "
These are the output relay contacts of the
detector. Connect to a normally closed or
normally opened zone in the control unit.
Terminals 7 & 8 - Marked " TAMPER "
If a Tamper function is required connect these
Terminals to a 24-hour normally closed protective
zone in the control unit.
10
For LR (Long Range ) mirror optic
Group A - positions 0 and 1 – set sensitivity for 40m
detection range
Group B - positions 6 and 7 – set sensitivity for28m
detection range
Group C - positions B and C – set sensitivity for
15m detection range
The 5 or 6 levels in each group are used to set up
the sensitivity according to environment.
Each range group includes 5 or 6 setting levels
according to environmental condition risk.
For example:
If detector is used for 15m range in open space with
sunlight – set switch to position 8 or 9.
MRX–220N DESCRIPTION
The MRX-220N is a combination of DOUBLE
DUAL PIR with MIRROR optics & MW detectors,
specially designed for outdoor and harsh
environment applications.
The Mirror DOUBLE DUAL detector MRX-220N
uses varifocal mirror that improves the focus and
the level of energy received by the Pyro Sensor.
This combination assures "false alarm free"
operation.
The 16 position rotate switch changes the MW
and PIR sensitivity so that the effective pattern
will be scaled.
INSTALLING THE DETECTOR
1. To remove the front cover, unscrew the
holding screw. Insert a screwdriver between
the front and the bottom and pull gently, until
the front cover is disengaged. (FIG 1)
2. Break out the desired holes for proper wiring
as per FIG 6.
3. Insert the wire through the wire access hole,
and mount the detector base to the wall with
the necessary number of screws.
4. Access for wiring connections is very easy
with the terminal block located on the PCB.
See FIG 3.
5. Replace the cover by inserting it back in the
appropriate closing, screw the holding screw.
If the front cover of the detector is opened, an
immediate alarm signal will be sent to the control
unit.
7
8
9
Terminals 6 & 9 - Marked " EOL "
End of line - options.
When an intruder is detected, alarm relays (N.O.
and N.C.) will switch for 1.8 sec.
WIRE SIZE REQUIREMENTS
Use #22 AWG or larger wires. Use the following
table to determine required wire gauge and length.
Wire Gauge:
Wire Length:
LED INDICATORS
YELLOW LED - MW detection, is blinking during
GREEN LED -
RED LED –
FIG.4 - ROTARY SWITCH SETTING
Installation Hight: 3m
Bracket Angle:
2
5
8
#
22
20
18
16
m
205
310
510
870
Ft.
800
1200 2000
3400
warm up period and self testing
PIR detection
Alarm
11
WA
Noise Area
F
Very High Risk
E
High Risk
D
LR
High Risk
Risk
C
Low Risk
Low Risk
B
A
9
0°
3
MRX–220N FEATURES
• DOUBLE DUAL PYRO sensor and full pattern
mirrors for outstanding detection performance
and elimination of false alarms.
• MW detection based on Doppler concept.
• FET based DRO with stripline antenna.
• VLSI based electronics with movement speed
spectrum analysis.
• N.O. & N. C. Relays switched at the same time.
• Height installation calibrations free from 1.5m to
3.0m (5ft to 10ft).
• Pet Immunity up to 10, 20, 30 or 40kg –
Selectable
• MW and PIR sensitivity adjustment.
• Environmental immunity.
• Temperature compensation.
6
FIG. 1 - REMOVAL OF FRONT COVER
FIG. 2 – BRACKET ASSEMBLY
9
SENSITIVITY AND RANGE ADJUSTMENT
The
calibration
of range and sensitivity is
performed by single digital 16 positional rotary
switch.
There are 3 groups of switch setting according to
detection range.
Each group is devided to levels of sensitivity
according to installation environment.
The value of sensitivity level is changed according
to optic
For WA (Wide Angle ) mirror optic
Group A - positions 0 – 5 – set sensitivity for 21m
detection range
Group B - positions 6 – A – set sensitivity for15m
detection range
Group C - positions B – F – set sensitivity for 7m
detection range
12
WA
Low Risk
Risk
0
1
High Risk
2
Very High Risk
3
Noise Area
4
Extreme Noise Area
5
WA
6
7
Low Risk
8
Risk
High Risk
Very High Risk
Noise Area
LR
Low Risk
High Risk
LR
Low Risk
High Risk