Dikkan DN300 사용 설명서 - 페이지 13
{카테고리_이름} Dikkan DN300에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dikkan DN300 17 페이지.
9. OPERATION
•
Globe valves are operated manually by handwheel. The handwheels are designed such that reasonable effort
exerted by the operators is sufficient to operate the valve. All Dikkan globe valves have open and closed marked
on the hand wheels along with directional arrow. To open, turn the handle in a counterclockwise direction. To
close, turn the handle in a clockwise direction. Whenever possible, open and close the valve slowly. This is
particularly important in piping systems containing liquids where quick valve closure (with other factors) could
lead to the possibility of an undesirable pressure surge (water hammer) in the piping system.
•
Level indicator models, you can follow the valve open- close rates on the level indicator.
•
If the hand wheel is difficult to turn, loosen packing nut ¼ to ½ turn. Retighten packing nut after open-close
operation is completed.
9.1 Bypass Disc
Valves with balancing plugs have to be installed with medium flowing over the plug (a) as indicated by flow direction
arrow on valve body. When the valve is closed, anticlockwise rotation of the hand wheel lifts the pilot plug (b) off the
larger balancing plug (a). This allows the medium to pass through the plug and equalizes the pressure of the medium
under the plug (a). After the pressures have been equalized within the values stated, the valve can be opened by turning
the valve further with normal manual force.
Doc. No: FRM.65
Rev. No: 00 Rev. Date: 01.06.2015
11