Dill 1502 매뉴얼 - 페이지 8

{카테고리_이름} Dill 1502에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dill 1502 16 페이지. Tpms trailer kit

Dill 1502 매뉴얼
The display is preprogramed to provide a warning if the pressure drops 20% below or
30% above the cold inflation pressure. It will also give a high temperature warning if
the temperature exceed 176°F. The high temperature warning point is not adjustable.
The system is shipped with the baseline (cold inflation) pressure set at 35 psi. At this
setting, the display will provide a low pressure warning at 28 psi and a high pressure
warning at 46 psi. You can set the baseline pressure (see Setting the Baseline (Cold
Inflation) pressure in Setting up the System on page 3) up to 144 psi and the display
will automatically provide a low pressure warning at 20% below and 30% above the
baseline setting.
Examples:
Cold Inflation
Low Pressure
Pressure
45 psi
65 psi
90 psi
FIGURE 7
Alarm
36 psi
52 psi
72 psi
8
High Pres-
sure Alarm
59 psi
85 psi
117 psi