Crown 460 CSL 참조 매뉴얼 - 페이지 8
{카테고리_이름} Crown 460 CSL에 대한 참조 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Crown 460 CSL 19 페이지. Crown 460csl: specifications
Crown 460 CSL에 대해서도 마찬가지입니다: 다이어그램 (2 페이지)

eration, distortion and excessive heating.
2.3 Input Sensitivity Adjustment
The input sensitivity switch inside the amplifier is set to
0.775 volts at the factory. It can be changed to 1.4 volts
or a voltage gain of 26 dB as follows:
1. Turn off and unplug the amplifier from the AC source.
2. Remove the access cover on the back panel.
3. Locate the labeled access hole for the sensitivity switch.
4. Set the switch to the desired position.
5. Replace the access cover plate.
When set to 26 dB gain, the 460 CSL requires a 2.0 volt
input, the 800 CSL requires a 2.5 volt input and the 1400
CSL requires a 3.2 volt input to deliver full output into an
8 ohm load.
2.4 Additional Load Protection
Because CSL amplifiers can generate enormous
power, it may be desirable to protect loudspeakers from
damage due to excessive power. A common way to do
this is to put a fuse in series with the load. This may be
accomplished with a single fuse to protect the entire
system, or by fusing each driver separately. Use Figure
2.4 to find the correct fuse.
Example: (A) Choose the peak music power for the loudspeaker
(such as 75 watts). (B) Find the loudspeaker impedance (8
ohms). (C) Draw a line between points A and B. The line inter-
sects the middle scale at the correct fuse value (1.5 amps).
Page 8
CSL Series Power Amplifiers
1.0
1.2
1.4
1.6
20
2
15
2.5
10
8
3
6
5
4
4
5
3
6
2
Example: Z = 8 ohms.
7
Peak Power = 75 W
1.5
8
Answer: Fuse = 1.5 A
1
9
.8
10
.6
12
.5
14
.4
16
.3
20
.2
25
.15
30
.1
.08
40
Fig. 2.4 Loudspeaker Fuse Nomograph
3000
2000
1500
1000
800
600
400
300
200
150
100
80
60
40
30
20
15
10
8
6
4
3
2
1.5
1