Fig. 6 - Showing the shellplate in its proper position:
under the ejector wire with the shellplate number up.
Fig. 7 - This photo shows the index star in its proper
position: the locating tabs centered in the shellplate.
Place the index sprocket on top of the shellplate
(making sure the locator posts go into the
corresponding holes in the shellplate, see Fig. 7).
Fig. 8 - Inserting the shellplate bolt, first through the index
sprocket then the shellplate.
Fig. 9 - This photo shows the proper method of
indexing the shellplate and the proper installation of
the locator buttons.
Next, insert the shellplate bolt through the
sprocket and plate and into the center hole of the
platform, Fig. 8. Tighten with the supplied Allen
wrench to the point where you are unable to turn the
sprocket by hand. Now, back off the bolt slightly,
allowing you to push the sprocket easily with your
thumb, Fig. 9. There should be no looseness or slop at
this point and when you rotate the plate, you should
be able to feel and hear the index ball "click" into
place under the shellplate.
8
* Indicates a caliber specific part. See the caliber conversion
chart on page 16 for the caliber you are loading for.