Motorola C380 서비스 매뉴얼 - 페이지 37
{카테고리_이름} Motorola C380에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Motorola C380 48 페이지. Quad-band wireless telephone
Motorola C380에 대해서도 마찬가지입니다: 매뉴얼 (26 페이지)
Level 1 and 2 Service Manual
Troubleshooting
Manual Test Mode
Manual Test Mode Commands
Table 4. Manual Test Commands
Key Sequence
<Menu>048263* Enter manual test mode
"End" Key
Exit manual test mode
54*
Suspend
0*0*0
Select tone 0
0*0*1
Select tone 1
0*0*2
Select tone 2
0*0*3
Select tone 3
0*0*4
Select tone 4
0*0*5
Select tone 5
0*0*6
Select tone 6
0*0*7
Select tone 7
0*0*8
Select tone 8
0*0*9
Select tone 9
0*0*124
Select tone 1 KHz
0*0*125
Select tone 2 KHz
0*0*126
Select tone 3 KHz
0*0*127
Select tone 4 KHz
0*1*X
Disable tone X
3*0*1
Enable vibrator
3*0*0
Disable vibrator
4*3*1
Enable speech coder full rate
4*3*0
Disable speech coder full rate
4*4*1
Enable speech coder enhanced full rate
4*4*0
Disable speech coder enhanced full rate
6809485A73-O
Motorola C380 telephones are equipped with a manual test mode capability. This
allows service personnel to verify functionality and perform fault isolation by
entering keypad commands.
To enter the manual test command mode, a GSM / DCS test SIM must be used.
Press O to turn the phone OFF.
1.
2.
Remove the battery as described in the procedures.
3.
Remove the customer's SIM card from the phone as described in the
procedures.
4.
Insert the test SIM into the SIM slot.
5.
Replace the battery as described in the procedures.
Press O to turn the phone ON.
6.
Test Function/Name
Required for all Test Mode Operations
Audio loopback
May 14, 2004
Troubleshooting
Remarks
37