Epson Equity I 제품 지원 게시판 - 페이지 2

{카테고리_이름} Epson Equity I에 대한 제품 지원 게시판을 온라인으로 검색하거나 PDF를 다운로드하세요. Epson Equity I 21 페이지. Product support bulletin(s)
Epson Equity I에 대해서도 마찬가지입니다: 제품 지원 게시판 (19 페이지), 제품 지원 게시판 (45 페이지)

Epson Equity I 제품 지원 게시판
Subject:
Equity/Apex Compatibility with the SOTA 386si
3/02/90
Page:
The purpose of this bulletin is to provide the 80386 Accelerator board test
results, conducted by the Computer Product Support Center, involving the
SOTA 386si from SOTA Technology, inc.
The Equity models tested were the Equity I, Equity II Equity I + and Equity le.
The Apex models tested were the Apex, Apex Plus and Apex 100. All were
tested with Norton Utilities and MS - DOS.
The table below shows compatibility and the Norton SI rating of the
various systems.
Model
Equity I+
Apex Plus
Product Support Bulletin
Norton SI
12.0
12.0/16.9
14.3
15.9
11.5
12.0/16.9
Compatibility
Functioned normally with Norton Utilities and
MS- DOS 2.11
Functioned normally with MS - DOS 3.3 and
Norton Utilities at both CPU speeds.
Unable to boot at 10MHz. Performance
erratic at 4.77MHz
Functioned normally with MS - DOS 3.2 and
Norton Utilities. (Tested only at 7.16MHz.)
Unable to boot at 4.77MHz. Functioned
normally at 8MHz with MS - DOS 3.2 and
Norton Utilities.
Unable to boot at 9.54MHz. Functioned
normally at 4.77MHz with MS - DOS 3.2 and
Norton Utilities.
Functioned normally with MS - DOS 3.3 and
Norton Utilities.
S-0111
Originator: