ing any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
1.
Remove unit from installed wall (remove trim surround,
if applicable).
2.
Remove the outer top panel mounting screws, (3 left
side, 3 back, 3 right side). Lift the panel off the firebox
and position heater assembly upright being careful not
to damage any wires.
3.
Remove the 3 heater assembly mounting screws from
underneath the top panel along the front.
4.
Lower the heater assembly so that the 3 support tabs,
in the top panel, can be easily released.
5.
Remove temperature limit switch screw from heater
bracket assembly and disconnect the temperature limit
switch wire from heater element and from the wire con-
nectors, noting their original location.
!
NOTE: To reconnect temperature limit switch, cut and
strip the long end of the cutout wire, and wire connect to
existing cutout wire closest to blower motor.
6.
Properly orient the new temperature limit switch and
secure to heater bracket assembly.
7.
Reconnect the wires in their original locations.
8.
Reassemble in the reverse order as above.
WARNINg: Ensure wires do not come in contact with
moving parts by securing wires in tie wraps.

ELEMENT REPLACEMENT

SECURED IN WALL

Tools Required: Philips head screwdriver
⅜" Hex head socket or ratchet
Needle nose pliers
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect circuit power before attempt-
ing any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
!
NOTE: The fireplace is equipped with two heating
elements. The same removal and installation instructions
apply to both elements.
1.
Open the steel curtains (remove glass doors if appli-
cable).
2.
Remove the 2 screws from the log set retaining plate
along the front of the log set and remove the retaining
plate.
3.
Pull the rear edge of the log set forward by grasping
the ember bed by the sides, pull firmly until the rear tab
pops out from under the back ledge, then lift the logs
out. (Figure 5)
!
IMPORTANT: Only handle the log-set by the plastic
ember-bed, not the logs themselves.
!
NOTE: Log-set fits tightly into firebox. Some force
may be necessary to remove.
4.
Disconnect the log set LED wire harness from unit.
(DXP MODELS ONLY)
5.
Release the steel curtains from the side panels by
opening the retainers on the sides of the fireplace using
needle nose pliers.
6.
Remove the steel curtains by lifting up on the curtain
mounting rod releasing it from the side mounting tab,
and pulling out.
7.
Remove the 2 filter retaining screws and remove the
filter and retaining plate.
8.
Remove the 10 mounting screws from inside the fire-
box that secures the interior top panel and remove the
heater cover.
9.
Locate the elements mounted to the top cover, pull the
sheathing back and disconnect the connections noting
their original locations.
10.
Remove the 2 element cover hex head screws on the
right using a ⅜" Hex head socket.
11.
Remove the 3 remaining element cover mounting
screws on the left and remove element.
12.
Properly orient the replacement element and reconnect
all of the wiring connections in their original locations.
13.
Reassemble in the reverse order as above.
!
NOTE: When re-inserting the log-set, insert the front
edge first then push the backside of the log-set down until
the rear tab snaps under the back partially reflective glass
ledge and the logs are resting against the partially reflective
glass.

REMOVABLE FROM WALL

Tools Required: Philips head screwdriver
⅜" Hex head socket or ratchet
Needle nose pliers
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect circuit power before attempt-
ing any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
!
NOTE: The fireplace is equipped with two heating
elements. The same removal and installation instructions
apply to both elements.
1.
Remove unit from installed wall. (Remove trim surround
if applicable).
2.
Remove the outer top panel mounting screws, (3-left
side, 3-back, 3-right side). Lift the panel off the firebox
and position heater assembly upright being careful not
to damage any wires.
3.
Locate the elements mounted to the top cover, pull
back the sheathing and disconnect the connections
noting their original locations.
4.
Remove the 2 element cover hex head screws on the
right using a ⅜" Hex head socket.
13