BFRC-kIT REMOTE CONTROL
RECEIVER INSTALLATION/
REPLACEMENT
Tools Required: Philips head screwdriver
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect circuit power before attempt-
ing any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
1.
Open the steel curtains (remove glass doors if appli-
cable).
2.
Remove the log retaining plate/grate located on the
lower panel along the front base of the log set, by re-
moving the screws that secure the plate to the firebox.
3.
Pull the rear edge of the log set forward by grasping
the ember bed by the sides (handle the log set only by
the ember bed and not the logs) and pulling firmly until
the rear tab pops out from under the back ledge, then
lift out. (Figure 5)
!
IMPORTANT: Only handle the log-set by the plastic
ember-bed, not the logs themselves.
!
NOTE: Log-set fits tightly into firebox. Some force
may be necessary to remove.
4.
Disconnect the log set LED wire harness from unit.
(DXP MODELS ONLY)
5.
Locate the removable bracket on the lower right side
of the fireplace and remove the 2 mounting screws
located to the left of the manual switches.
6.
Remove the bracket - turn the back edge toward the
light bulb about 1/2" (12.7mm) then lift straight up.
7.
Depressing both tabs on either side of the quick con-
nect plug and unplug it from the unit.
8.
Locate the plug connector on the new assembly.
9.
Position the antenna wire so that it is under the new
bracket, plug in and install the bracket into position.
!
NOTE: The plug only will fit in one way so it may need
to be rotated to be inserted.
10.
Locate and install the two screws on the new remote
control panel.
11.
Replace the log by inserting front edge and pushing
the back down until rear tab snaps under back ledge
(Figure 5) and the logs are resting against partially
reflective glass.
!
NOTE: When re-inserting the log-set, insert the front
edge first then push the backside of the log-set down until
the rear tab snaps under the back partially reflective glass
ledge and the logs are resting against the partially reflective
glass.
12.
Replace log grate, using two screws previously re-
moved.
13.
Initialize the remote control to the new receiver installed
in the fireplace as per the instructions included in the
remote packaging.
WRCPF-kIT WALL CONTROLLER
INSTALLATION/REPLACEMENT
Tools Required: Philips head screwdriver
WARNINg: If the fireplace was operating prior to
servicing allow at least 10 minutes for light bulbs and
heating elements to cool off to avoid accidental burning
of skin.
WARNINg: Disconnect circuit power before attempt-
ing any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
1.
Open the steel curtains (remove glass doors if appli-
cable).
2.
Remove the log retaining plate/grate located on the
lower panel along the front base of the log set, by re-
moving the screws that secure the plate to the firebox.
3.
Pull the rear edge of the log set forward by grasping
the ember bed by the sides (handle the log set only by
the ember bed and not the logs) and pulling firmly until
the rear tab pops out from under the back ledge, then
lift out. (Figure 5)
!
IMPORTANT: Only handle the log-set by the plastic
ember-bed, not the logs themselves.
!
NOTE: Log-set fits tightly into firebox. Some force
may be necessary to remove.
4.
Disconnect the log set LED wire harness from unit.
(DXP MODELS ONLY)
5.
Locate the removable bracket on the lower right side
of the fireplace and remove the 2 mounting screws
located to the left of the switches.
6.
Remove the bracket - turn the back edge toward the
light bulb about 1/2" (12.7mm) then lift straight up.
7.
Depressing both tabs on either side of the plug connec-
tor unplug it from the unit.
8.
Locate the plug connector on the new assembly.
9.
Position the antenna wire so that it is under the new
bracket, plug in and install the bracket into position.
10.
Locate and install the two screws on the remote control
panel.
11.
Replace the log by inserting front edge and pushing
the back down until rear tab snaps under back ledge
(Figure 5) and the logs are resting against partially
reflective glass.
!
NOTE: When re-inserting the log-set, insert the front
edge first then push the backside of the log-set down until
the rear tab snaps under the back partially reflective glass
ledge and the logs are resting against the partially reflective
glass.
12.
Replace log grate, using two screws previously re-
moved.
13.
Mount the wall controller within a standard electrical
device box, located within 50ft (15m) of the firebox and
15