ing the screws to prevent the unit from falling.
3. Remove the fireplace out of the opening by slightly lift-
ing and pulling forward.
4. Carefully lay the unit down on a solid flat surface with
the front of the unit facing up.
!
NOTE: If the surface you are using as a work area is a
finished surface that is prone to scratches (i.e. hardwood
flooring), it is recommended that a protective barrier be
used underneath, (i.e. cloth, cardboard, thick plastic).
Figure 7
Mounting
holes
Figure 8
Wall Surface
Mounting Hole
Mounting hole
5. Proceed to the instructions within this manual relating
to the repair being performed - see Table of Contents
for page number.
6. Once repair is complete, reassemble in the reverse
order as above.
ON/OFF SWITCH REPLACEMENT
WARNING: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
CAUTION: If unit was operating prior to servicing allow
at least 10 minutes for lights and heating elements to cool
off to avoid accidental burning of skin.
Tools required: Phillips head screwdriver.
Needle nosed pliers.
CAUTION: Follow "Preparation for Service" instructions
before proceeding.
1. Remove the 2 screws, that secure the controls assem-
bly (Figure 9), located at the top of the mirror on the
right side of the unit.
2. Slide the controls assembly out toward the front of the
unit.
CAUTION: Ensure that the assembly is removed care-
fully, ensuring that no wires are caught or over strained.
Figure 9
Controls Assembly
Figure 10
LED
Driver Board
Remote
Receiver
Retaining Screws
On/Off
Switch
Switch
Board