Fireplace Installation
Figure 3
Wall stud
Key-hole
Permanent
mounting hole
• Lay fireplace on its back.
• Remove two (2) Phillips
screws from each of the two
(2) glass brackets (Figure 2).
• Remove glass brackets.
• With one hand keeping
pressure on the partially
reflective glass, tilt the
fireplace upright and slightly
forward to allow the partially
reflective glass to fall out of
the inside framing.
• Remove partially reflective
glass from fireplace.
4. Position the fireplace on a wall
at the position where it will be
mounted (Figure 3). Use a
bubble level (one is supplied)
to ensure that fireplace is level
on the wall.
10
5. Mark the location of four (4)
screw locations on the wall
(through key-holes).
CAUTION: If installing unit on
a wall that is constructed of
drywall ensure that appropriate
wall anchors are used and at
least one is located into a stud.
6. Remove fireplace from wall
and store in a safe place
away from traffic.
7. Screw all four (4) supplied #8,
3.8 cm square head mounting
screws and washers into
the wall and/or wall anchors
leaving 6.5 mm of thread.
8. Align chosen key-holes with
screws and hang fireplace
on the wall. Screw heads
and washers will fit through
key-holes and fireplace will
slide down into place (screws
will slide into narrow part of
key-holes).
9. Tighten all four (4) mounting
screws down on fireplace
chassis.
10. Screw the two (2) supplied
#8 square head screws
through two of the permanent
mounting holes which align
with a wall stud.
11. Carefully replace and install
www.dimplex.co.uk
Fireplace Installation
partially reflective glass and
glass brackets using screws
from step 1.
12. Refer to Front Glass
Installation section, for final
installation procedures.
In-wall Recessed
Installation - 100mm Deep
CAUTION: Two people may
be required for various steps
of this procedure.
1. Prepare a wall with a framed
opening of 118.1 cm wide x
42 cm high (Figure 4).
!
NOTE: The sizing has allowed
for 6.4mm around the fireplace
insert for ease of installation. This
fireplace does not require any
additional venting.
2. Choose your method of
supplying power to the unit:
• Plug in (you may run the
power cord out of the framed
wall opening to an existing
outlet or install an outlet on
a nearby wall stud within the
wall).
• Hard wire the fireplace.
!
NOTE: Hard wiring can
be done by removing the plug
from the factory fitted cord and
Figure 4
Figure 5
Mounting
holes
11