Cruise N Comfort HD 12L 설치 및 운영 지침 매뉴얼 - 페이지 2
{카테고리_이름} Cruise N Comfort HD 12L에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cruise N Comfort HD 12L 11 페이지. 12 volt air conditioners
Cruise N Comfort HD 12L에 대해서도 마찬가지입니다: 설치 및 운영 지침 매뉴얼 (7 페이지)
3.
Run #6 and #8 Refrigerant hoses from Evaporator to condenser (make sure the green O ring is inside the
fitting). Tighten fittings with open end wrenches. Do not loop lines or have excessive low points. Try to keep
hoses close to 7 feet or less.
4.
Run the supplied condenser wire from Evaporator Box to
black, solder together and shrink wrap.
9.
Run the primary 4 gauge or larger power wires from the A/C unit to the battery no longer than 7 feet. Install a
70 amp marine grade explosion proof resettable circuit breaker to the positive wire at battery terminal.
10. Connect manual A/C Control unit or optional thermostat .
11.
Connect the power and ground connections to the unit fig.8 (make sure the power switch is in the off position).
Do not remove the compressors power ring terminals that are already installed. Tighten securely. Make
Sure All Electric Connects are Crimped And Terminal Lugs Are Tight.
14. Connect 4" insulated non conductive vent hose to unit no longer than 6 feet and run hose to area that is to be
cooled. Remember for best results aim the vent toward the person to be cooled. Mount vent or ducting
assembly and connect hose be sure to use non conductive hose with a non conductive fastener because of
the close proximity of the main power terminal. Failure to do so could cause a short or fire. For best results,
make sure that air from the cooled area can be returned with ease to the A/C air inlet on the front of the
unit. The best way of doing this is to mount the unit in the area that is being cooled . By recycling cool air,
unit will provide coldest air possible. Do not mount this unit in a engine area or where exhaust and gas
fumes can be exposed to this unit. This unit is NOT explosion proof!! NEVER operate unit without cover
in place and secured!!
15. Connect 1/4 tubing to the 2 brass fittings on the evaporator tray. run the tubes to the outside of the vehicle.
Condenser Fan. Connect red to red and black to
Page
2
of
11