3Com WL-306 테스트 지침 - 페이지 2

{카테고리_이름} 3Com WL-306에 대한 테스트 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. 3Com WL-306 4 페이지.

3Com WL-306 테스트 지침
2) Setting the WL-306 into Trasmission
Type in the following commands precisely during test noting the spaces and case
(upper/lower) of the commands. Note you only need to enter the commands in BOLD.
r 0
{This will turn the receive mode off and enable you to transmit}
c 1
{This will select channel 1. Similarly you can perform testing on any of
the other channels by typing "c x" where x is the channel number}.
a 1
{This will select antenna connection B. Alternatively you can choose Antenna
connection A using command "a 0" however this is the default setting so it is not
required unless you are changing from Antenna B to A}.
pc 127 {Modifies power level setting from 143 to 127}
tc
{Transmit mode = Continuous}
{Note: The above "tc" command sets a continuous number of packets which will be
transmitted after the "T" command below is initiated. If you only need to transmit for a
shorter time you can limit the number of packets by using the "t xxxxx" command where
xxxx is the number of packets. For example t 3000 will transmit for approximately 1
minute. Simply increase the number accordingly for the time required.
T
{Start transmitting}
{You can check the power level using the command "pc" only once the "T" command
has started transmission. Use of this command at any other time may cause the power
level to default to an incorrect power level setting}
Changing Channels:
Once the WL-306 is transmitting, as detailed above, the channels can be changed simply
as follows. At the Debugging enabled prompt type:
c x
{You can set the channel to anywhere between 1-14 by entering this command
where x is the channel number required. The new channel should adopt the same
properties (e.g. power levels etc) as the previous channel. If you are in any doubt
as to whether this is the case then remove the orange cable from the WL-306, re-
insert the cable and then repeat the commands from 2) above this time entering
the new required channel number}
Turning On/Off modulation:
You can select a signal with or without modulation using the following commands once
the WL-306 is transmitting.
At the Debugging enabled prompt type:
cw 0
{Turns on modulation}
cw 1