11.4 Technical Data
Heat pump for cooling of domestic water
Type
Nominal tank capacity
Tank material
Nominal tank pressure
Dimensions
( height x width x depth [without tube connections] )
Weight
Electrical connection ( plug-in device – cable length approx.
Fusing
Refrigerant R 134a, charge weight
Performance data
Temperature, operating range (air)
Water temperature, selectable (heat pump mode)
Heat-up time from 25° C to 65 °C (electr. immersion heater)
Power consumption, electric heating
Average power consumption
Average cooling capacity
Cooling-down time from 45°C to 20°C
Air flow rate:
External pressure
Maximum airduct connection length
Airduct connection, diameter
Connection
domestic water outlet
Connection
domestic water supply
1) The cooling process of the nominal tank content from 45°C to 20°C at an air intake temperature of 35 °C
1)
at 45 °C (at 60 Hz)
1)
at 45 °C (at 60 Hz)
1)
(total)
( litres)
( bar )
( cm )
( kg )
)
2.7 m
( A )
( kg )
( °C)
( °C )
( h )
( watt )
( watt )
( watt )
( h )
3
( m
/ h )
( Pa )
( m )
( mm )
external thread
external thread
KWP 300
compact unit
300
enamelled steel acc. to
10
169 x 66 x 66
approx. 110
230V ~ 50 or 60 Hz
16
1.0
20 to 45
16 to 25
9.2
1500
850
1450
6.5
585
110
10
160
R1"
R1"
DIN 4753