Dimplex OMWFC20 사용자 설명서 - 페이지 10
{카테고리_이름} Dimplex OMWFC20에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dimplex OMWFC20 12 페이지. Optimyst wall engine
Dimplex OMWFC20에 대해서도 마찬가지입니다: 사용자 설명서 (12 페이지)
Troubleshooting
Symptom
The flame effect will
not start.
The flame effect is too
low.
Unpleasant smell when
unit is used.
The flame effect has
too much smoke.
Main lamps are not
working and there are
no flames or smoke.
Cause
Mains plug is not plugged in.
Low water level.
Low voltage connector not connected properly.
(See Fig.6)
The Transducer Unit is not sitting correctly in
the sump
Flame effect control knob is set too low.
(See Fig.2)
The Metal Disc in the transducer might be dirty
(See Fig.12)
The wire from the Transducer Unit is sitting over
the metal disc
Dirty or stale water.
Using unfiltered tap water.
Flame effect setting is too high.
There is no water in the water tank
Corrective Action
Check plug is connected to wall socket correctly.
Check that the water tank is full and there is
water in the sump.
Check that the connector is inserted correctly.
(See Fig.6)
Ensure the Transducer in sitting down into the
moulded recess in the sump
Increase level of flame by turning Control knob
'D' anti clockwise slowly. (See Fig.2)
Clean the Metal Disc with soft brush supplied.
(See Fig.12) See 'Maintenance. ' for a step by step
procedure.
Direct the wire to the back of the sump and
make sure it sits into the side slot exiting the
sump.
Clean the unit as described under maintenance.
Use only filtered tap water.
Turn the flame effect Control knob C clockwise,
about ¼ a turn, at a time. Give the flame
generator some time to adjust to the new
setting. (See Fig.2)
Follow instructions under
Maintenance, 'Filling the water tank' .
Check the plug is connected to the wall socket
correctly and that Switch 'A' Fig. 2 is in the
'ON' ( I ) position.